The objective of this study is to evaluate the safety and performance of AdvanCore implantable bone graft through a 12-month follow-up period in a prospective, parallel-group design, non-controlled, open label, multi-center and real-world setting study. This study is intended to satisfy post-market clinical follow-up requirements of CE Mark in Europe.
Full description
AdvanCore is a porous beta-tricalcium phosphate CE-marked medical device. It is intended to be used to aid in the bone regeneration process in situations where bone is damaged beyond the limits of its self-healing ability. The target population is constituted by adult subjects in need of bone grafting of mechanically unaffected, pathologic, or traumatic bone defects caused by surgery or trauma.
AdvanCore is produced in the shape of blocks, wedges, or granules in different sizes and is surgically placed into spaces between or around broken bone (fractures) or in holes (defects). The site to be augmented must be free from infection and free from soft or granulation tissue. AdvanCore must contact cancelous bone and may be pressed into the defect area by hand or shaped more accurately to fit the area. It can be used as is, impregnated with subjects' blood/ bone marrow and/ or mixed with medicinal substances under the responsibility of the qualified professionals.
AdvanCore acts as a temporary scaffold and is not intended to provide mechanical support during the healing process. Additional therapy for load-bearing (such as osteosynthesis) is indicated if the bone does not comply with the required biomechanical function.
The study on safety and performance of AdvanCore bone void filler will be conducted in European sites and include up to 190 subjects requiring bone implant surgery, which will be divided in 3 different groups:
The primary safety endpoint of this study is defined as freedom of bone reintervention due to AdvanCore usage at 6 months, analyzing the occurrence of Adverse Events or Serious Adverse Events [(S)AEs] related to the device usage and/ or AdvanCore procedure that may lead to subjects' reoperation.
The primary performance endpoint will analyze the AdvanCore osteointegration after 6 months of surgery, studying the percentage of subjects with successful osteointegration at the defined time point. AdvanCore will be considered successfully osteointegrated when no presence of fibrotic tissue surrounding the implant is detected.
Secondary endpoints planned for this clinical investigation are listed below:
The clinical investigation has been designed to involve as little pain, discomfort, fear, and any other foreseeable risk as possible for subjects.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
190 participants in 3 patient groups