ClinicalTrials.Veeva

Menu

Study on the Patient-Ventilator Asynchrony Analysis Function

M

Ming Zhong

Status

Not yet enrolling

Conditions

To Study the Incidence of Patient-ventilator Asynchronization in Two Groups of Patients Under Two Conditions With PVA Unsynchronization Analysis Function

Treatments

Device: PVA recognition function

Study type

Interventional

Funder types

Other

Identifiers

NCT06390917
B2024-082

Details and patient eligibility

About

In this study, the incidence of patient-ventilator asynchronism in two groups of patients was studied when the ventilator was prompted by the PVA asynchronism analysis function

Full description

Incidence of patient-computer dyssynchrony events: defined as the proportion of patient-computer dyssynchrony events in the total number of cycles during the patient trial. The observation period began 48 hours after the participants met the inclusion and exclusion criteria and signed the informed consent, and the data collection was stopped 48 hours later.

Enrollment

30 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Adults (≥18 years) requiring invasive mechanical ventilation
  2. Patiens had spontaneous breathing;
  3. Agreed to participate in the trial and signed an informed consent

Exclusion criteria

  1. Patients with contraindications to esophageal catheter insertion and inability to monitor esophageal pressure;
  2. pregnant women;
  3. patients with severe central nervous system damage or neuromuscular related diseases;
  4. Participating in other clinical research projects;
  5. Patients deemed unsuitable by the investigator

Trial design

Primary purpose

Other

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

30 participants in 2 patient groups

With PVAs group
Experimental group
Description:
With the assistance of PVA function, researchers identify the patient-ventilator asynchronies and take actions to reduce the asynchronies.
Treatment:
Device: PVA recognition function
Without PVAs group
No Intervention group
Description:
PVA function is not utilized in this arm, researchers identify the patient-ventilator asynchronies by their own and take actions to reduce the asynchronies.

Trial contacts and locations

0

Loading...

Central trial contact

Yaxiaerjiang Muhetaer; Ming Zhong

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems