ClinicalTrials.Veeva

Menu

Study to Evaluate Safety & Effectiveness of Vascular Sealant System

Integra LifeSciences logo

Integra LifeSciences

Status

Terminated

Conditions

Peripheral Vascular Disease

Treatments

Device: Gelfoam/Thrombin
Device: VascuSeal

Study type

Interventional

Funder types

Industry

Identifiers

NCT00439309
VAS-06-001

Details and patient eligibility

About

To evaluate a new vascular sealant compared to control for the control of suture line bleeding after vascular reconstructive surgery.

Full description

Vascular surgery encompasses a wide range of surgical procedures. In these procedures reduction of blood loss and creation of suture line is of utmost importance to the surgeon. Bleeding at the suture line may require transfusion, as well as prolonged operative and anesthesia time. Suture hole bleeding is common following using synthetic and biological grafts for vascular repair. Several topical hemostatic ans sealing agents have been developed to control suture line bleeding. This new vascular sealant possess high bonding properties, minimal tissue reaction, is biodegradable and absorbed by the body quickly. The primary focus of this study is to compare the safety and effectiveness of the vascular sealant with standard of care methods used today, specifically gelfoam/thrombin and sponge like material.

Enrollment

69 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Subject was > 18 years of age. Scheduled for elective vascular surgery that entails placement of a PTFE vascular graft including extra-anatomic, infrainguinal bypass, and primary and secondary arteriovenous access procedures. Subject was willing and able to comply with all aspects of the treatment and evaluation schedule. Informed of the nature of the study, and has provided written informed consent, approved by the appropriate Institutional Review Board (IRB) of the respective clinical site

Exclusion criteria

Subject had a known local or systemic infection. Subjects with known coagulopathies including hemophilia, factor deficiencies, platelet count < 80,000 u/mL, heparin induced thrombocytopenia or uncorrected INR > 1.5. Subject was participating in a clinical trial that requires treatment with another investigational device or drug. Subject was lactating or pregnant, or does not agree to use contraception for the duration of the study. Subject had a known hypersensitivity to any components of bovine thrombin preparations and/or material of bovine origin. The investigator determined that the subject should not be included in the study for reason(s) not already specified

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

69 participants in 2 patient groups

VascuSeal
Experimental group
Description:
Consists of two liquids that when mixed together in situ rapidly cross-link to form a biocompatible absorbable sealant that is tissue adherent. These liquids are sprayed onto tissues using the Dual Liquid Applicator. The formed Sealant remains intact for approximately 2 to 7 days. During this period the Sealant undergoes hydrolysis where it is absorbed into the circulatory system and is excreted through the kidneys.
Treatment:
Device: VascuSeal
GELFOAM/THROMBIN
Active Comparator group
Description:
GELFOAM/THROMBIN description - GELFOAM Sterile Compressed Sponge is a medical device intended for application to bleeding surfaces as a hemostatic. It is water-insoluble, off-white, nonelastic, porous, pliable product prepared from purified porcine Skin Gelatin USP Granulates and Water for Injection, USP. It may be cut without fraying and is able to absorb and hold within its interstices, many times its weight of blood and other fluids. Although not necessary, GELFOAM can be used either with or without thrombin to obtain hemostasis.
Treatment:
Device: Gelfoam/Thrombin