The MADIT-II trial has shown that patients with severely reduced left ventricular ejection fraction (LVEF) post myocardial infarction benefit from the implantable cardioverter-defibrillator (ICD). However, retrospective analyses of the MADIT-II data have revealed a significantly increased morbidity and mortality in patients with appropriate ICD therapy: Appropriate ICD therapy is associated with 3.3-fold increased all-cause mortality, and the risk of a first heart failure hospitalization is 90% higher after 1st appropriate ICD therapy. Hence, the 1st appropriate therapy might indicate the necessity and utility of further clinical diagnostics and therapy in these patients.
This trial is designed to (i) improve the knowledge of the group characteristics of patients suffering from 1st appropriate ICD therapy, (ii) but moreover to take additional therapeutic steps to reduce the mortality of this patient population.
Full description
The MADIT-II trial has shown that patients with severely reduced left ventricular ejection fraction (LVEF) post myocardial infarction benefit from the implantable cardioverter-defibrillator (ICD). However, retrospective analyses of the MADIT-II data have revealed a significantly increased morbidity and mortality in patients with appropriate ICD therapy: Appropriate ICD therapy is associated with 3.3-fold increased all-cause mortality, and the risk of a first heart failure hospitalization is 90% higher after 1st appropriate ICD therapy. Hence, the 1st appropriate therapy might indicate the necessity and utility of further clinical diagnostics and therapy in these patients.
This trial is designed to (i) improve the knowledge of the group characteristics of patients suffering from 1st appropriate ICD therapy, (ii) but moreover to take additional therapeutic steps to reduce the mortality of this patient population.
After standard ICD implantation procedure, the following steps are performed at the pre-discharge follow-up:
Programming: VR-T: VVI 40 ppm, Onset 20%, Stability 20 ms
DR-T: DDD 50-60 ppm, activation of IRSplus and SMART
HF-T: DDD-BiV 50-60 ppm, achieve at least 85% biventricular resynchronisation, activation of SMART
All devices: VT zone as therapy zone, VF zone. Programming recommendations for VT/VF zones to standardize treatment:
Activation of Home Monitoring (HM) and online registration for HM service
Standard Follow-up: Timing and scope of follow-up in patients without episodes is to the physician's own discretion and should follow the standard clinical routine.
Follow-up after 1st appropriate ICD therapy: Immediately after having received the 1st appropriate ICD therapy, the patients have to be called to the clinic for intensified clinical diagnostics and, if necessary or useful, intensified therapy. Standard ICD follow-up has to be started within 72 hours after 1st appropriate ICD therapy.
Final follow-up visit: For patients without appropriate ICD therapy, the final follow-up shall be performed 12 months after enrolment.
For patients with appropriate ICD therapy, the final follow-up shall be performed 12 months after 1st appropriate ICD therapy.
The final follow-up visit comprises:
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Indication for ICD implantation according to MADIT-II:
Angiography within the preceding 12 months
The patient is willing and able to comply with the clinical investigation plan and has provided written informed consent
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
504 participants in 2 patient groups