SWITCH - Sensing With Insulin Pump Therapy to Control HbA1c

Medtronic logo

Medtronic

Status

Completed

Conditions

Diabetes Mellitus, Type 1

Treatments

Device: insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System)
Device: insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump)

Study type

Interventional

Funder types

Industry

Identifiers

NCT00598663
ISRCTN09806152
EUR03

Details and patient eligibility

About

The primary objective of this study is to evaluate whether the patients with Type 1 diabetes mellitus in sub-optimal glycemic control can achieve better glycemic control by using the Medtronic MiniMed Paradigm® REAL-Time Pump System with continuous glucose monitoring versus the Medtronic MiniMed Paradigm® REAL-Time Pump alone with Self Monitoring Blood Glucose (SMBG).Our null hypothesis is there is a 0% reduction in HbA1c from baseline compared to control group, after 6 months of treatment.

Enrollment

153 patients

Sex

All

Ages

6 to 70 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Type 1 diabetes mellitus diagnosed for at least 12 months prior to signature of informed consent,
  • Sub-optimal glycemic control (7.5%<HbA1c<9.5%).
  • Patient treated by continuous subcutaneous insulin infusion (CSII) for at least 6 months prior signature of informed consent.
  • Patient treated within the practice of the investigator's center at least 6 months prior signature of informed consent.
  • Patient has no preliminary experience with the sensor function of the Paradigm REAL-Time or the Guardian® REAL-Time for the 4 months prior signature of informed consent.

Exclusion criteria

  • Existing pregnancy or intention to conceive (as assessed by investigator).
  • Hearing or vision impairment so that glucose display and alarms cannot be recognized.
  • Three or more incidents in the last 12 months of severe hypoglycaemia with documented Blood Glucose below 50mg/dL (if possible), resulting in unconsciousness, hospitalisation or third party assistance, where recovery follows treatment with glucose or glucagon or similar.
  • History of hypoglycemic unawareness as assessed by the investigator.
  • Alcohol or drug abuse, other than nicotine.
  • Documented cutaneous allergy or disease (allergy to sensor or components of the sensor, psoriasis, staphylococcus, exanthema etc.).
  • Any documented concomitant chronic disease known to affect diabetes control (e.g. altered renal function, active cancer undergoing treatment, Crohn's disease, ulcerative colitis, Mb Addison disease) or any concomitant pharmacological treatment that might modify glycemic values (e.g chronic corticosteroid therapy), eating disorders and morbid obesity (defined as adults : Body Mass Index >35 and children Body Mass Index > 2 standard deviations. for age) as assessed by the investigator.
  • Any other medical, social or psychological condition that, in the investigator's opinion, makes the patient unable to comply with the study protocol and all study procedures.
  • For pediatric subjects: does not have a reliable support person.
  • Plans to travel for extended periods (3+ weeks) where the devices cannot be supplied or replaced and/or medical support is limited (eg. exotic countries, remote places).
  • Participation in another clinical study, on-going or completed less than 3 months prior to signature of Patient Informed Consent.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

153 participants in 2 patient groups

Off/On
Experimental group
Description:
6 month-Period Off: Continuous Subcutaneous Insulin Infusion (CSII) and Self Monitoring Blood Glucose \[Device: Paradigm® Real-Time pump with Sensor Off feature\] 4 month wash out period 6 month-Period On: Continuous Subcutaneous Insulin Infusion (CSII) + personal continuous glucose monitoring (personal CGM) \[Device: Paradigm® Real-Time pump with Sensor On feature continuously\]
Treatment:
Device: insulin pump with continuous glucose sensing (Paradigm Real-Time Insulin Pump System)
On/Off
Experimental group
Description:
6 month-Period On: Continuous Subcutaneous Insulin Infusion (CSII) + personal continuous glucose monitoring (personal CGM) \[Device: Paradigm® Real-Time pump with Sensor On feature continuously\] 4 month wash out period 6 month-Period Off: Continuous Subcutaneous Insulin Infusion (CSII) and Self Monitoring Blood Glucose \[Device: Paradigm® Real-Time pump with Sensor Off feature\]
Treatment:
Device: insulin pump and blinded continuous glucose sensing (Paradigm Real-Time insulin pump)