Details and patient eligibility

About

This multicenter, prospective, observational study aims to evaluate the efficacy and safety of thoracic endovascular aortic repair (TEVAR) combined with false lumen embolization using vascular plugs in patients with acute type B aortic dissection. Despite TEVAR being a standard treatment for type B dissection, long-term outcomes remain suboptimal due to persistent false lumen perfusion through distal re-entry tears, leading to aortic expansion and high reintervention rates. This study addresses the clinical need for a more definitive treatment strategy that promotes complete false lumen thrombosis and aortic remodeling.

The study plans to enroll 72 subjects across multiple centers in China, with each participant followed for 12 months. Key inclusion criteria comprise patients with acute or subacute (≤30 days from onset) type B aortic dissection exhibiting typical symptoms and extending to the infrarenal aorta, who are scheduled for the combined procedure. Exclusion criteria included those requiring emergency surgery, complicated dissections with malperfusion or rupture, trauma-related or infectious etiologies, prior aortic surgery, uncontrolled systemic diseases, recent myocardial infarction or stroke, and patients outside the 18-80 age range or refusing participation.

The primary efficacy endpoint is the complete thrombosis rate of the false lumen in the thoracic aorta at 12 months postoperatively, while the primary safety endpoint is the incidence of major adverse events (MAEs) at the same time point. MAEs are defined as a composite of all-cause mortality, myocardial infarction, respiratory failure requiring prolonged ventilation or reintubation, renal deterioration (>50% reduction in eGFR or new dialysis), bowel ischemia requiring surgery or refractory to medical therapy, major stroke, and grade 3 paraplegia. Secondary endpoints include thrombosis rates at 1 and 6 months in the thoracic aorta, patency and thrombosis status at the celiac trunk and infrarenal aortic levels at 1, 6, and 12 months, incidence of MAEs at earlier timepoints, and rates of endoleaks and reinterventions.

All subjects will receive a standardized treatment protocol involving TEVAR with stent-graft placement to seal the proximal entry tear, followed by selective catheterization of the false lumen and deployment of 1-3 vascular plugs at predetermined locations: one parallel to the distal edge of the thoracic stent-graft, one at the level of the celiac trunk, and one at the distal re-entry tear in the infrarenal aorta. Follow-up assessments are scheduled at 1, 6, and 12 months post-procedure, including clinical evaluation and thoracoabdominal CTA imaging to assess aortic remodeling and complication status.

This investigation represents the first prospective multicenter effort to evaluate the combined TEVAR and false lumen embolization strategy. By addressing the fundamental limitation of conventional TEVAR-incomplete false lumen exclusion-this study may establish a new standard for achieving complete aortic remodeling in type B dissection. The results are anticipated to provide robust evidence for guiding clinical practice and potentially influencing future treatment guidelines in aortic disease management.

Enrollment

72 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria

Patients must meet all of the following conditions to be enrolled:

  1. Diagnosed with acute or subacute (symptom onset ≤30 days) Stanford type B aortic dissection.
  2. Present with typical clinical symptoms and imaging-confirmed aortic dissection.
  3. Dissection extends distally to involve the infrarenal abdominal aorta.
  4. Scheduled to undergo elective TEVAR combined with false lumen embolization.

Exclusion Criteria

Patients will be excluded if they meet any of the following conditions:

  1. Requiring emergency surgery due to rupture, impending rupture, or severe malperfusion.
  2. Complicated type B dissection (e.g., visceral/limb ischemia, refractory pain, or hemodynamic instability).
  3. Suspected traumatic or infectious etiology of the dissection.
  4. Previous history of aortic surgery or endovascular repair.
  5. Use of alternative techniques during the procedure (e.g., PETTICOAT, long-segment coverage).
  6. Uncontrolled systemic diseases (e.g., severe cardiac/pulmonary/hepatic dysfunction, advanced malignancy, cachexia, or uncorrectable coagulation disorders).
  7. Myocardial infarction or stroke within the past 6 months.
  8. Age <18 years or >80 years.
  9. Patient refusal to participate in the study.

Trial design

72 participants in 1 patient group

Group 1: TEVAR with false lumen embolization
Description:
Patients with type B aortic dissection who receive TEAVR in the true lumen and vascular plug embolization in the false lumen
Treatment:
Device: TEAVR with false lumen embolization

Trial contacts and locations

0

Loading...

Central trial contact

Hongkun Zhang, M.D.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems