Status
Conditions
Treatments
About
Obtaining peripheral vascular access in medical patients is a necessary procedure for many healthcare providers. Peripheral vascular access is traditionally performed using palpation or visual inspection to identify appropriate points of entry in the vasculature after which a needle and catheter are threaded through the skin and surround fascia into the vessel of interest. This procedure, one of the most common procedures in the medical field including both artery and vein access, is not 100% successfully attempted. Operator skill heavily influences peripheral vascular cannulation. (Frisch et al. 2013) However, certain patient populations have difficult peripheral vessels to identify by palpation or visual inspection and past operators would be forced to perform the procedure blind based on anatomical landmarks. Recently, to aid vascular identification and increase cannulation success, a number of alternative techniques for peripheral vascular access have been described including ultrasound-guided.
Ultrasound-guided vascular access has been utilized in vascular access with improved success rate. However, even with ultrasound guidance the first attempt success rate of cannulation was only approximately 65%. A proposed failure of ultrasound guided peripheral vascular access is most likely due to failure to advance the catheter into the vessel even the vessel was successfully punctured. The investigators propose a specific technique and the positive "Target Sign" as a means to obtain almost 100% successful peripheral vascular access.
The investigators plan to enroll 100 surgical patients in the above study and study procedures will not differ from what a patient in the operating room under the care of anesthesia faculty would receive. The above study is simply a way to identify the steps regarding a specific technique.
Full description
The subjects (patients) will be brought to the Main Operating Room after their time in the Day of Surgery Admissions (DOSA) at the discretion of the attending physicians and surgical team. The patients will not be required to do anything different from standard anesthesia and surgical practice at the hospital. Subjects will come to the operating room suite and the usual monitors (electrocardiogram, non-invasive blood pressure, and oxygen saturation) will be placed.
Prior to the routine induction of anesthesia, peripheral vascular access is usually obtained. In regards to the subject population, peripheral vascular access is predicted to be more difficult due to lack of visualization of the peripheral vessels. The skin will be prepped with chlorhexidine, draped, and all subsequent procedures will be performed in sterile fashion. The attending physician and/or resident will use the L25x Sonosite transducer with the Sonosite Edge® (Washington, US) to identify a peripheral vessel in the upper extremity for cannulation. After identification of the vessel, the operator will line the L25x Sonosite transducer to place the vessel horizontally midline on the Sonosite Edge® screen to give the most available viewing area. A BD Insyte® Autoguard® 16G shielded IV catheter (Becton Dickinson Infusion Therapy Systems Inc., Utah, US) will be advanced toward the vessel at an approximately 10˚ angle. Once the needle tip is identified on the Sonosite Edge® monitor in short axis view, the following steps will ensue:
Advance the needle toward the vessel slowly, adjusting the ultrasound transducer position and angle to continue to keep the needle tip and vessel identified on the Sonosite Edge® monitor.
Puncture the anterior wall of the vessel with the needle tip
Confirm needle tip placement in vessel
Advance the needle within the vessel 5mm under continuous visualization
View and record confirmation of "Target Sign" on ultrasound monitor
Thread the catheter over the needle.
At this point, the catheter could be advanced either with or without a guidewire at the operator's discretion Members of the research team will be available for verbal assistance throughout this procedure.
Number of attempts and time to successful vessel cannulation will be measured, starting from when either the operator's fingers or the ultrasound probe made contact with the patient's skin. Successful vessel cannulation will be defined as a flowing IV bag of saline after connection and confirmation of flow via fluid agitation in vessel identified via ultrasound.
This procedure will be incorporated in the subjects standard of care and will not extend the time of operation.
At this point, patient participation in the study will be over and surgical operation under the discretion of the surgical team. The video recording of the Target Sign will be saved and given to a member of the research team unknowing of the success of the cannulation. The member of the research team will decide, based on the ultrasound video recording of a positive or negative Target Sign, if the cannulation was successful or unsuccessful. The viewer will record his/her answers and compare with the actual result of the cannulation.
Analysis of unsuccessful and successful cannulations will be compared with a Positive or Negative Target Sign. No additional long-term followup will occur.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
100 participants in 1 patient group