Temporary Epicardial Pace Wire With Integrated Sensor for Continuous Postoperative Monitoring of Myocardial Function

C

Cardiaccs

Status

Invitation-only

Conditions

Cardiac Disease
Myocardial Dysfunction

Treatments

Device: CS1 System

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT04886934
2020-004776-17

Details and patient eligibility

About

Transesophageal echocardiography is used to monitor cardiac wall motion at various time points during open-heart surgery. After surgery, the measurements are made at various time points by transthoracic echocardiography.

The CS1 system enables continuous, direct measurement of cardiac wall motion. This is achieved through use of temporary pacemaker wires incorporating a motion detector called an accelerometer. Use of TMEs during and after open-heart surgery is part of the normal clinical routine. Continuous monitoring of cardiac wall motion during and after surgery can quickly highlight the need for medical intervention with cardiac drugs and allow very early detection of potentially serious complications leading to abnormal cardiac wall motion.

Cardiac wall motion activity registered by the CS1 system and echocardiography at specific time points during and after surgery will be analyzed to see how well they compare.

Full description

Echocardiography is currently the most important and most widely used tool in cardiology besides electrocardiography (ECG). It is reliable for assessing all stages of cardiovascular disease, and it is commonly used to detect heart (cardiac) wall motion dysfunction during and after open-heart surgery.

During open-heart surgery, transesophageal echocardiography (when the echocardiography sensor is introduced into the esophagus) is used to monitor cardiac wall motion at various time points during surgery. After surgery, the measurements are made at various time points by transthoracic echocardiography (when the echocardiography sensor is placed on the chest wall).

Use of the CS1 system enables continuous, direct measurements of cardiac wall motion. This is achieved through use of temporary pacemaker wires (also called temporary myocardial electrodes or TMEs) incorporating a motion detector called an accelerometer. Use of TMEs during and after open-heart surgery is part of the normal clinical routine. Continuous monitoring of cardiac wall motion during the surgery and the post-surgical recovery period can, for example, quickly highlight the need for medical intervention with cardiac drugs and allow very early detection of potentially serious complications such as ischemia (heart muscle is not receiving enough oxygen) and myocardial dysfunction (cardiac wall motion appears abnormal).

The key feature of the CS1 system is that the cardiac wall motion activity registered by the novel TMEs incorporating the accelerometer are displayed visually on a standard medical monitor and synchronized with the patient's ECG data. These data can easily be viewed by medical staff to check if the patient's condition is satisfactory or whether medical intervention is needed.

In the study, the CS1 system will be used in addition to the standard monitoring procedures that include ECG, blood pressures and intermittent echocardiography. Cardiac wall motion activity registered by the CS1 system and echocardiography at specific time points during and after surgery will be analyzed to see how well they compare.

Enrollment

38 estimated patients

Sex

All

Ages

19 to 99 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Patients with heart disease requiring surgery
  2. Above 18 years
  3. Patients suitable for study participation without safety concerns based on the Investigator's evaluation of medical history and physical examination.
  4. The patient must be able to understand the aims and objectives of the trial, willing and able to comply with all study related procedures
  5. The patient must be willing and able to provide written informed consent prior to participation in the clinical investigation
  6. The patient agrees to abstain from enrollment in any other clinical investigation for the duration of the study

Exclusion criteria

  1. Esophageal disease
  2. Atrial fibrillation
  3. Pregnancy

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

38 participants in 1 patient group

Safety and clinical performance of the CS1 system
Experimental group
Description:
Placement of the CS1 device on the left ventricle and externalization of the associated leads through the chest wall during open-heart surgery.
Treatment:
Device: CS1 System