ClinicalTrials.Veeva

Menu

The Application Value of da Vinci Linear Cutting Stapler SureForm in Robotic Anus Preserving Surgery for Rectal Cancer

N

Nanchang University

Status

Enrolling

Conditions

Laparoscopic
Robotic
Anastomotic Leak
Rectal Cancer

Treatments

Device: Surform

Study type

Interventional

Funder types

Other

Identifiers

NCT05667181
IIT2022155

Details and patient eligibility

About

Anastomotic complications are serious complications after anus preserving surgery for rectal cancer,the instrument anastomosis technology are one of the factors that influence the occurrence of anastomotic complications after surgery,the laparoscopic linear cutting closure device used in robotic rectal cancer may increase the occurrence of anastomotic complications,but the robot linear cutting stapler (SureForm) may reduce the incidence of postoperative anastomotic complications due to the technical advantages,therefore,the aim of this study is to evaluate the impact of robotic linear cutting stapler SureForm and laparoscopic linear cutting stapler on the incidence of anastomotic complications after robotic rectal cancer anus preserving surgery.

Full description

Anastomotic complications are serious complications after anus preserving surgery for rectal cancer, including anastomotic leakage, anastomotic bleeding, and anastomotic stenosis, with a incidence rate of 1.6% - 20.5% . The occurrence of anastomotic complications increases the perioperative mortality, hospital stay, and hospital costs of patients, and even some patients with severe anastomotic complications need to be re operated after surgery, which seriously affects the quality of life of patients. More research shows that , The complications of anastomotic stoma lead to the delay of postoperative adjuvant therapy, which increases the local recurrence rate of tumor. Therefore, how to reduce the occurrence of anastomotic complications in anus preserving surgery for rectal cancer has always been the focus of surgeons.

A variety of factors are involved in the occurrence of anastomotic complications after surgery, including gender, patient's general condition, tumor size and distance from anal margin, and instrument anastomosis technology . It is believed that , when using a closer to break the rectum during radical resection of rectal cancer, the use of multiple nail cages will increase the incidence of postoperative anastomotic complications. In the past, laparoscopic rectal cutting staplers were used in robotic radical resection of rectal cancer, and most of them were completed with the cooperation of assistants. In difficult cases, the mechanical arm needed to be removed and the main knife was used to perform rectal resection. In addition, the laparoscopic linear cutting closure device was cumbersome and complicated, and it often needed to use multiple nail silos to cut rectum in a narrow pelvic cavity, resulting in uneven anastomosis quality, Increase the occurrence of anastomotic complications. In recent years, the robot company has developed a new software driven robot assisted stapler (SureForm). The stapler can be directly loaded onto the mechanical arm. When the rectum is broken, the main knife can independently control it on the console. It has a joint head that rotates 60 ° from top to bottom, left to right, a 120 ° cone range of motion, and a 540 ° wrist joint design of the rod body, so that the stapler jaws can be vertically placed and separated from the rectum, The utility model can reduce the use of the nail bin when the rectum is transected, thereby reducing the incidence of postoperative anastomotic complications.

At present, only a few foreign studies have reported the application of robot linear cutting stapler SureForm in anus preserving surgery for rectal cancer, and the studies are retrospective, with a small sample size. There is no report in China. Therefore, this study adopts a prospective randomized controlled study method to evaluate the impact of robotic linear cutting stapler SureForm and laparoscopic linear cutting stapler on the incidence of anastomotic complications after robotic rectal cancer anus preserving surgery, so as to provide a reference for the application of robotic linear cutting stapler SureForm in robotic anus preserving surgery.

Enrollment

276 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. The age is more than 18 years old and less than or equal to 75 years old
  2. Pathological diagnosis of rectal adenocarcinoma by colonoscopy biopsy
  3. The distance between the tumor and the anal margin diagnosed by colonoscopy and pelvic MRI before operation is less than or equal to 15cm
  4. No distant metastasis (including pelvic cavity, peritoneum, liver, lung, brain, bone, distant lymph node metastasis, etc.) is judged by ultrasound, CT, PET-CT, etc
  5. No local complications before operation (no obstruction, incomplete obstruction, no massive active bleeding, no perforation, abscess formation, no local invasion)
  6. Robot surgery
  7. Voluntary participation and signing of informed consent

Exclusion criteria

  1. Previous history of malignant colorectal tumors
  2. Simultaneous diagnosis of multiple primary colorectal tumors
  3. Those who have performed abdominal and pelvic surgery for many times or have extensive abdominal adhesions
  4. Patients with familial adenomatous polyposis, Lynch syndrome associated rectal cancer, and inflammatory bowel disease at active stage
  5. Diagnosis of other malignant tumors in recent 5 years
  6. ASA grade ≥ IV and/or ECOG physical status score ≥ 2
  7. Patients with severe liver and kidney function, heart and lung function, blood coagulation dysfunction or combined with severe basic diseases can not tolerate surgery
  8. Preventive ileostomy
  9. Patients undergoing combined abdominal and perineal resection

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

276 participants in 2 patient groups

robotic group
Experimental group
Description:
Robot linear cutting stapler
Treatment:
Device: Surform
laparocaopic group
Active Comparator group
Description:
laparoscopic linear cutting stapler
Treatment:
Device: Surform

Trial contacts and locations

1

Loading...

Central trial contact

li taiyuan, doctor

Data sourced from clinicaltrials.gov