This study aims to use a combination of abbreviated protocol and artificial intelligence to automatically identify lesions and make diagnosis without decreasing the diagnostic accuracy of breast cancer, thus enhancing the comfort of patient examination, accelerating the flow of examination and reducing the load of clinical work.
Full description
Full sequence of MRI scan is:
MR scan protocol:
Imaging parameters: the thickness of the scanned layer should be ≤3 mm, the resolution within the layer should be <1.5 mm, and the single scan time should be <2 min.
Enhancement scan: Gadobutrol used as the contrast agent, and the injection dose was 0.1 ml/kg, which was injected through the elbow vein at a rate of 2-3 mL/s using a pressure syringe, and 10-20 mL of saline was injected into the tube at the same rate after the contrast agent injection. The T1WI sequences before and after enhancement were preferably fat-suppressed and bilateral mammary glands were imaged simultaneously, and subtraction treatment was recommended. The recommended duration of delayed enhancement scan is 7 min, not less than 5 min.
Abbreviated sequences : T1WI + dynamic enhanced T1 phase I + maximum density projection images generated by automatic reconstruction in three directions. No extra sequences are required.
By adding artificial inteeligence, a diagnostic performance comparable with full sequences is expected.