ClinicalTrials.Veeva

Menu

The Consistency of Cardiac Output Measurements by Different Methods in VA-ECMO Patients

Fudan University logo

Fudan University

Status

Enrolling

Conditions

Extracorporeal Membrane Oxygenation

Treatments

Diagnostic Test: dobutamine stress test
Diagnostic Test: Trendelenburg Maneuver

Study type

Interventional

Funder types

Other

Identifiers

NCT04102072
COMMENT

Details and patient eligibility

About

Objective:

  1. To evaluate the consistency of cardiac output measured by different hemodynamic monitoring methods in patients with VA-ECMO
  2. To evaluate whether different hemodynamic monitoring methods can accurately detect the trend of cardiac output changes

Full description

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) has been used for profound cardiogenic shock to bridge to decision,ventricular assist devices,or transplant.Close monitoring of cardiac output, especially in patients before and after intervention (such as volume expansion, diuresis, vasoconstriction, vasodilation therapy), can help to adjust the treatment strategy. Hemodynamic monitoring in ECMO patients requires familiarity with the underlying pathophysiology and circulatory mechanics of extracorporeal flow.Limited to the actual clinical situation of patients, one or two hemodynamic monitoring methods may be accepted. Is there consistency between different hemodynamic monitoring results? And whether hemodynamic monitoring can accurately detect the changes of these parameters before and after intervention is an important issue in clinical practice. This study will provide important reference for VA-ECMO patients how to choose appropriate hemodynamic monitoring tools and how to interpret the results of hemodynamic monitoring.

Enrollment

20 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. cardiac surgery
  2. treatment with VA-ECMO
  3. mechanical ventilation
  4. hemodynamic monitoring according to patient's condition (PAC, Flotrac, echocardiography)

Exclusion criteria

  1. age < 18
  2. cardiac arrhythmia
  3. moderate to severe aortic, mitral and tricuspid regurgitation
  4. active hemorrhage
  5. IABP
  6. spontaneous triggering of the ventilator

Trial design

Primary purpose

Treatment

Allocation

Non-Randomized

Interventional model

Single Group Assignment

Masking

None (Open label)

20 participants in 2 patient groups

Trendelenburg Maneuver
Experimental group
Description:
The Trendelenburg position is a common treatment in medicine.It is used either as a diagnostic tool to assess fluid loading response or as a therapeutic maneuver pending fluid resuscitation.With the advantage of autotransfusion readily available,the Trendelenburg position is used for expected instantaneous effect on cardiovascular performance.
Treatment:
Diagnostic Test: Trendelenburg Maneuver
dobutamine stress test
Experimental group
Description:
Dobutamine is a selective beta 1 receptor agonist. It \[\<10 ug/(kg.min)\] can effectively increase myocardial contractility.
Treatment:
Diagnostic Test: dobutamine stress test

Trial contacts and locations

1

Loading...

Central trial contact

Jun-yi Hou, Doctor; Guo-wei Tu, Doctor