ClinicalTrials.Veeva

Menu

The Effect of Lying Position on Hemodynamic Parameters in Patients With Mechanical Ventilated and Spontaneously Breathing.

A

Aydin Adnan Menderes University

Status

Completed

Conditions

Hemodynamic Instability
Position Sense Disorders

Treatments

Other: lying positions

Study type

Interventional

Funder types

Other

Identifiers

NCT06538051
position

Details and patient eligibility

About

Aim: The study was carried out to examine the effect of lying positions on hemodynamic parameters in patients with mechanical ventilation (MV) and spontaneous breathing.

Material and Methods: The research was carried out semi-experimentally with a single-group posttest design, between November 2021 and May 2022 in the Internal Medicine Intensive Care (ICU) Unit a University Hospital. The study of the sample consisted of 60 patients in the ICU. Data were collected with the patient identification form and the hemodynamic parameters follow-up form. The patients were given different lying positions for 3 days. Hemodynamic parameters were measured and recorded at the 10th minute, 1st hour and 2nd hour after position changes. The measurement results obtained were compared with one-way ANOVA test.

Full description

Aim: The study was carried out to examine the effect of lying positions on hemodynamic parameters in patients with mechanical ventilation (MV) and spontaneous breathing.

Material and Methods: The research was carried out semi-experimentally with a single-group posttest design, between the dates of 15.11.2021 and 15.05.2022 in the Internal Medicine Intensive Care (ICU) Unit a University Hospital. Since repeated measurements were planned in the study when determining the sample, A-priori power analysis was performed based on ANOVA repeated measures analysis and the effect size was calculated according to the etasquared value (Abd El-Aziz et al., 2021). Accordingly, the sample of the study was calculated as 34 patients to reach at least 80% power within a 95% confidence interval. The research was completed with a total of 60 patients who were spontaneously breathing (n=30) and mechanically ventilated (n=30). Data were collected with the patient identification form and the hemodynamic parameters follow-up form. Right lateral, semi Fowler's, left lateral and supine positions were applied to the patients every 2 hours between 9 am 5 pm for 3 days and then pulse rate, respiratory rate, systolic blood pressure (SBP), diastolic blood pressure (DBP) and oxygen saturation (SpO₂) were measured at 10th minute, 1st hour and 2nd hour. In data analysis, number, arithmetic mean, standard deviation, chi-square, independent groups t test and one-way ANOVA test were used.

Enrollment

60 patients

Sex

All

Ages

18 to 85 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Hospitalized in intensive care for at least 3 days
  • over 18 years of age
  • monitored
  • spontaneously breathing or connected to a mechanical ventilator,
  • conscious or unconscious,
  • receiving or not receiving oxygen support,
  • with or without a tracheostomy,
  • hemoglobin level of 8g/dl.

Exclusion criteria

  • Patients with movement restrictions
  • inotropic/vasopressor and sedative group medications
  • body temperature of 38˚C and above
  • patients receiving CPAP (Continuous Positive Airway Pressure) treatment

Trial design

Primary purpose

Supportive Care

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

60 participants in 1 patient group

lying positions
Other group
Treatment:
Other: lying positions

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems