The Effect of Trabeculectomy & Ex-PRESS Glaucoma Drainage Implant on the Corneal Biomechanical Properties

D

Democritus University of Thrace

Status

Completed

Conditions

Glaucoma Eye

Treatments

Procedure: Ex-Press mini shunt insertion
Procedure: Trabeculectomy

Study type

Interventional

Funder types

Other

Identifiers

NCT04648943
ES8/Th11/10-10-2013

Details and patient eligibility

About

This study aims to look into the change of the corneal biomechanical properties in patients undergoing insertion of the Ex-PRESS mini shunt or trabeculectomy for medically uncontrolled glaucoma

Full description

The patients in the study were divided into two groups. In group 1 the patients had the Ex-PRESS mini shunt inserted in the operated eye and in group 2 the patients underwent standard trabeculectomy.

The corneal biomechanical properties were measured with the Ocular Response Analyzer before surgery and at 1, 6 and 12 months after surgery. The corneal biomechanical properties measured were the Corneal Hysteresis (CH) and the Corneal Resistance Factor (CRF).

The change of the CH and CRF was compared in each group before and after surgery (at the aforementioned predetermined time points) and between the two groups.

The intraocular pressure was also measured with the Goldmann applanation tonometer at the same time points and the change was compared before and after surgery in each group and between the two groups.

Enrollment

26 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Age > 18
  • Average Intraocular pressure > 24 mmHg on at least 2 occasions 1 month before surgery
  • Congenital glaucoma

Exclusion criteria

  • Previous ocular trauma
  • Previous ocular surgery other than phacoemulsification
  • Previous disease of the ocular surface

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

26 participants in 2 patient groups

Patients undergoing Ex-Press mini shunt insertion
Active Comparator group
Description:
Patients in this arm had the Ex-Press mini shunt inserted in the operated eye in order to reduce the Intraocular Pressure. The corneal biomechanical properties were measured before and at 1, 6 and 12 months after surgery with the Ocular Response Analyzer
Treatment:
Procedure: Ex-Press mini shunt insertion
Patients undergoing trabeculectomy
Active Comparator group
Description:
Patients in this arm had standard trabeculectomy in the operated eye in order to reduce the Intraocular Pressure. The corneal biomechanical properties were measured before and at 1, 6 and 12 months after surgery with the Ocular Response Analyzer
Treatment:
Procedure: Trabeculectomy