The Effect of Various External Pressure on Blood (EPB)

H

Hyub Huh

Status

Completed

Conditions

Hemorrhage

Treatments

Device: Auto PC(Acemedical, Goyang-si, Korea) - 200mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 250mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 150mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 300mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 0mmHg(control)

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Rapid infusion of blood is needed occasionally for control massive bleeding. For rapid infusion, external pressure can be used. The investigators will study correlation between external pressure and hemolysis and deformability of red blood cell.

Full description

Rapid infusion of blood is needed occasionally for control massive bleeding. For rapid infusion, external pressure can be used which cause hemolysis and alteration of red blood cell. The investigators will study correlation between variable external pressure and hemolysis and deformability of red blood cell. Differ from previous study, the investigator will use scanning electron microscope for observation red blood cell.

Enrollment

25 patients

Sex

All

Ages

20 to 50 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • healthy volunteers, without any underlying disease.

Exclusion criteria

  • history of delivery, abortion in past 6 months.
  • weight : male under 50kg, female under 45kg
  • heart rate under 50 or over 100
  • fever : over 37.5
  • blood pressure : over 180/100

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

25 participants in 2 patient groups

5days
Active Comparator group
Description:
5 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.
Treatment:
Device: Auto PC(Acemedical, Goyang-si, Korea) - 250mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 0mmHg(control)
Device: Auto PC(Acemedical, Goyang-si, Korea) - 150mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 300mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 200mmHg
35days
Active Comparator group
Description:
35 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.
Treatment:
Device: Auto PC(Acemedical, Goyang-si, Korea) - 250mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 0mmHg(control)
Device: Auto PC(Acemedical, Goyang-si, Korea) - 150mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 300mmHg
Device: Auto PC(Acemedical, Goyang-si, Korea) - 200mmHg

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems