ClinicalTrials.Veeva

Menu

The Effects of the STAR Maneuver on UGRA Training

University of New Mexico (UNM) logo

University of New Mexico (UNM)

Status

Completed

Conditions

Simulator-based Training of Ultrasound-guided Regional Anesthesia

Treatments

Behavioral: ART
Behavioral: STAR

Study type

Interventional

Funder types

Other

Identifiers

NCT02032420
STAR vs. ART

Details and patient eligibility

About

Volunteers will watch a training video demonstrating how to place a needle in the correct position while keeping it visible. Later the volunteers will be placed in front of a set up identical to the video, and asked to demonstrate how to direct an 80 mm echogenic Pajunk needle into 3 targets in a standardized homemade phantom a total of three times.

Full description

After watching the training video, each volunteer will be placed in front of a set up identical to the video seen. Adjacent to this set up, a single fellowship trained regional anesthesiologist known as the assessor is situated with a screen that allows real time viewing of the ultrasound screen seen by the volunteer. The assessor is blinded to the assignment of the volunteer. Also, the assessor does not have any visualization of the volunteer. This prevents visualizing hand or body movement that may cause a bias. The same assessor is used for the whole study to provide consistent assessment of the task.

The task involves the volunteer directing an 80 mm echogenic Pajunk needle into 3 targets in a standardized homemade phantom. The targets simulate the nerve roots commonly found in the interscalene block. Thus, they are arranged diagonally to simulate the nerve root position commonly seen. Also, they are arranged on a tilt relative to the flat surface of the phantom to simulate the direction the nerve travels. This is important as the tilt of the target requires the volunteer to tilt the probe so that their incidental ultrasound wave is perpendicular to the target for the brightest reflection to occur. This phenomenon is known as anisotropy. This increases the realism of the task that cannot be imitated by commercially available phantoms.

There are 3 goals that the volunteer must fulfill in performing their task. Firstly, they must direct the needle to the 12 o'clock position of the 3 targets. Secondly, they must achieve maximal ultrasound image brightness of the 3 targets at all times. Thirdly, the entire needle must be visualized at all times.

If the needle is not in the correct position, the assessor will verbally inform the volunteer to redirect it to the correct position. If the target images are not at their brightest, the assessor will verbally inform the volunteer not to manipulate the needle towards the target until the targets are at their brightest. Clinically, this functions to prevent the needle being inserted inside the nerve as the targets are not clearly seen. Thirdly, if the needle is visualized entirely, the volunteer will be told to stop manipulating the needle towards the target until the needle is fully visualized by manipulating the probe. A timer records the cumulative time the needle is not in full visualization. Clinically, this functions to prevent the needle being inserted into a nerve or structure that it should not.

After all 3 targets have been completed, the volunteer repeats the task a total of 3 times.

Enrollment

35 patients

Sex

All

Ages

18 to 55 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Healthy volunteers
  • Right handed
  • Aged 18 to 55

Exclusion criteria

  • Any person who has prior knowledge about ultrasound imaging or regional anesthesia
  • Any person who has prior experience with laparoscopy or biopsy
  • Any person who has problems with depth of field or simple hand eye co-ordination task

Trial design

Primary purpose

Health Services Research

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

35 participants in 2 patient groups

STAR
Experimental group
Description:
Introductory training by video depicting 4 sequential maneuvers for reacquisition of needle image in ultrasound: see, tilt, align, rotate.
Treatment:
Behavioral: STAR
ART
Active Comparator group
Description:
Introductory training with a video depicting 3 probe position aspects for reacquisition of needle image by ultrasound: alignment, rotation, tilt.
Treatment:
Behavioral: ART

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2024 Veeva Systems