ClinicalTrials.Veeva

Menu

The Efficacies of The New Paclitaxel-Eluting CoroflexTM Please Stent in Percutaneous Coronary Intervention

Seoul National University logo

Seoul National University

Status and phase

Unknown
Phase 3

Conditions

Coronary Artery Disease

Treatments

Device: Coroflex Please stent implantation
Device: Taxus stent implantation

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT00699543
ECO-PLEASANT

Details and patient eligibility

About

Objectives

: To evaluate the clinical efficacy, angiographic outcomes, and safety of the new paclitaxel-eluting coronary stent (CoroflexTM Please, B Braun, Germany), compared with another paclitaxel-eluting coronary stent system (TaxusTM, Boston Scientific, USA) in the treatment of coronary stenosis.

Study Design

: Prospective, open label, 2: 1 randomized multi-center trial. Patients will be randomized according to the type of drug eluting stent ( CoroflexTM Please vs. TaxusTM). Randomization will also be stratified per hospital for the presence of DM and the presence of long lesions (lesion length > 28mm)

Patient Enrollment

:915 patients enrolled at 13 centers in Korea.

Patient Follow-Up

:Clinical follow-up will occur at 1, 4, 9, 12 months and 2, 3years after intervention. Investigator or designee may conduct follow-up as telephone contacts or office visits.

Primary Endpoint

:Clinically driven Target vessel Revascularization (TVR) at 9 months.

Secondary Endpoints

:A. Clinical safety and efficacy end points

  1. Major Cardiac Adverse Events (MACE; All Death, cardiac death, Myocardial infarction (Q-wave and non-Q wave), TVR)
  2. Target Vessel Failure (TVF; cardiovascular death, myocardial infarction, clinically driven TVR)
  3. Stent thrombosis

B. Angiographic efficacy end points

  1. in-stent binary restenosis by QCA
  2. in-stent and in-lesion late loss by QCA
  3. in-stent and in-lesion MLD and percentage diameter stenosis by QCA immediately after the index procedure and at 9 months of follow-up

Enrollment

915 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria

  • General Inclusion Criteria

    1. Subject must be at least 18 years of age.
    2. Subject is able to verbally confirm understandings of risks, benefits and treatment alternatives of receiving the CoroflexTM Please stent and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure.
    3. Subject must have coronary artery stenosis (>50% by visual estimate) with evidence of myocardial ischemia (e.g., stable, unstable angina, myocardial infarction, silent ischemia, positive functional study or a reversible changes in the electrocardiogram (ECG) consistent with ischemia.) or Subject must have significant coronary artery stenosis (>70% by visual estimate)
  • Angiographic Inclusion Criteria

    1. Target lesion(s) must be located in a native coronary artery with visually estimated diameter of ≥ 2.5 mm and ≤ 4.0 mm.
    2. Target lesion(s) must be amenable for percutaneous coronary intervention

Exclusion Criteria

  • General Exclusion Criteria

    1. The patient has a known hypersensitivity or contraindication to any of the following medications:

      • Heparin
      • Aspirin
      • Both Clopidogrel and Ticlopidine
      • Paclitaxel
      • Stainless steel
      • Contrast media(*) (*)Patients with documented sensitivity to contrast media which can be effectively pre-medicated with steroids and diphenhydramine [e.g. rash] may be enrolled. Those with true anaphylaxis to prior contrast media, however, should not be enrolled.
    2. Systemic (intravenous) Paclitaxel use within 12 months.

    3. Female of childbearing potential, unless a recent pregnancy test is negative, who possibly plan to become pregnant any time after enrollment into this study.

    4. History of bleeding diathesis or known coagulopathy (including heparin- induced thrombocytopenia), or will refuse blood transfusions.

    5. Gastrointestinal or genitourinary bleeding within the prior 3 months, or major surgery within 2 months.

    6. An elective surgical procedure is planned that would necessitate interruption of thienopyridines during the first 6 months post enrollment.

    7. Non-cardiac co-morbid conditions are present with life expectancy <1 year or that may result in protocol non-compliance (per site investigator's medical judgment).

    8. Patients who are actively participating in another drug or device investigational study, which have not completed the primary endpoint follow-up period.

    9. Patients with LVEF<25% or those with cardiogenic shock

    10. Patients with acute ST elevation myocardial infarction who requires primary PCI

    11. Patients with acute ST elevation myocardial infarction within 48hrs

    12. Creatinine level ≥ 3.0mg/dL or dependence on dialysis.

  • Angiographic Exclusion Criteria

    1. Patients with significant left main stem stenosis which requires revascularization therapy
    2. Patients who's target lesion has in-stent restenosis at the stented segment of drug-eluting stents or bare metal stents
    3. Target lesions with bifurcating disease which require side branch stenting

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

915 participants in 2 patient groups

C
Experimental group
Description:
Coroflex Please stent implantation
Treatment:
Device: Coroflex Please stent implantation
T
Active Comparator group
Description:
Taxus stent implantation
Treatment:
Device: Taxus stent implantation

Trial contacts and locations

0

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems