ClinicalTrials.Veeva

Menu

The Efficacy of Three Different Limus Agent-Eluting Stents to Prevent Restenosis (ISAR-TEST-2)

G

German Heart Center Munich

Status and phase

Completed
Phase 4

Conditions

Coronary Disease

Treatments

Device: Rapamycin-eluting Stent
Device: Zotarolimus-eluting Stent

Study type

Interventional

Funder types

Other

Identifiers

NCT00332397
GE IDE No. S02206

Details and patient eligibility

About

The purpose of this study is to evaluate the efficacy of 3 different drug-eluting-stent platforms to reduce coronary artery reblockage after stent implantation

Full description

Coronary artery reblockage remains still a drawback of percutaneous coronary interventions even in the era of drug-eluting stents (DES). DESs working principle consists of the delivery of controlled amounts of antiproliferative agents at the local level, which results in the suppression of neontimal proliferation, the main cause of lumen re-narrowing after stent implantation.At present, several DES platforms have been developed and evaluated for clinical use. They differ between them with regard to the stent type, anti-proliferative drug, presence of polymers employed for drug storage and modification of drug-release kinetics as well as type of polymer used for this purpose. Most of the DES platforms have used agents from the "limus family". Although the majority of DESs employ polymer coating to control drug storage and release, in view of the increasing safety and efficacy associated with the long-term presence of polymers a strong interest has recently been shown in the development DES platforms that do not require permanent polymers. Trials as ACTION or JUPITER II have demonstrated that not all DESs are associated with the expected improved outcomes. On the other hand, not all successful DESs have been equally effective in the reduction of restenosis. Thus, rapamycin-eluting stents (Cypher stents) have been associated with lower angiographic and clinical restenosis rates than paclitaxel-eluting stents (Taxus stents). Similarly, Cypher stents have been superior to Endeavor stents regarding the primary end point of late luminal loss in the recent ENDEAVOR III trial. Meanwhile, the on-site rapamycin-coated stents (ISAR stents) had an equivalent antiproliferative efficacy to Taxus stents in the ISAR-TEST trial. However, none of these studies evaluated angiographic restenosis as their primary endpoint and no direct comparisons between the 3 DES -Cypher, Endeavor and ISAR stents, have been performed. The Cypher stent is a stainless steel stent coated with sirolimus with use of permanent polymers while the Endeavor stent is a cobalt alloy based stent coated with zotarolimus which also uses permanent polymers for drug-storage and release. The ISAR stent is a rough surface stainless steel stent that can be coated with sirolimus in the cath lab without requiring permanent polymeric coating.

Enrollment

1,007 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Patients older than age 18 ´ presence of ischemic symptoms or evidence of myocardial ischemia in the presence of ≥50% de novo stenosis located in native coronary vessels written, informed consent by the patient or her/his legally-authorized representative for participation in the study.

Exclusion criteria

Target lesion located in the left main trunk or bypass graft In-stent restenosis Cardiogenic shock Malignancies or other comorbid conditions with life expectancy less than one year or that may result in protocol non-compliance Known allergy to the study medications: aspirin, clopidogrel, zotarolimus, sirolimus, stainless steel, or cobalt alloy Pregnancy (present, suspected or planned) or positive pregnancy test Previous enrollment in this trial Patient's inability to fully cooperate with the study protocol

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

1,007 participants in 3 patient groups

A
Active Comparator group
Description:
Rapamycin-eluting Stent (Cypher)
Treatment:
Device: Rapamycin-eluting Stent
Device: Rapamycin-eluting Stent
B
Active Comparator group
Description:
Zotarolimus-eluting Stent (Endeavor)
Treatment:
Device: Zotarolimus-eluting Stent
C
Active Comparator group
Description:
Rapamycin-eluting Stent
Treatment:
Device: Rapamycin-eluting Stent
Device: Rapamycin-eluting Stent