ClinicalTrials.Veeva

Menu

EO Footprint as a Landmark During DAA THA

U

Universitaire Ziekenhuizen KU Leuven

Status

Completed

Conditions

Coxarthrosis

Treatments

Procedure: Total Hip arthroplasty via a Direct Anterior Approach

Study type

Observational

Funder types

Other

Identifiers

Details and patient eligibility

About

One of the goals of Total Hip Arthroplasty (THA) is to reconstruct leg length as adequately as possible. In order to achieve this one needs landmarks that are visible both on the templating X ray as well as during surgery. The classical posterior and lateral approaches often rely on the distance from the greater trochanter (GT) to the shoulder of the femoral stem or the distance from the lesser trochanter (LT) to the side of the neck osteotomy. If the surgeon finds out on the digital template that the distance from the GT to the shoulder of the implant should be X mm to achieve equal leg length, than the surgeon can try to reconstruct this during surgery. During the Direct Anterior Approach (DAA) these landmarks usually are not visible or require additional dissection injuring important soft tissue structures along the way. One anatomical structure that appears to be always visible during the DAA is the External Obturator tendon (EO). It was recently confirmed that the level of insertion of the EO onto the proximal femur can also always be determined on pre-operative X rays. It therefore represents one of the few landmarks that is visible both on the templating X ray as well as during DAA THA. Indeed, many hip surgeons, including ourselves, believe that if the shoulder of the femoral stem is near the insertion of the EO leg length cannot be far off. However, there is no clinical data to support this. The investigators would therefore like to the correlate the distance observed intra-operatively to the actual established distance on the post-operative X ray.

Enrollment

135 patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion criteria

  • All patient who underwent THA via DAA by a single surgeon who routinely documents the distance from the shoulder of the stem to the upper border of the EO tendon

Exclusion criteria

  • Distance not noted
  • No radiographs available

Trial design

135 participants in 1 patient group

Patients who underwent DAA THA
Description:
Patients who underwent DAA THA by a single surgeon who routinely documents the distance from the should of the stem to the upper end of the EO footprint
Treatment:
Procedure: Total Hip arthroplasty via a Direct Anterior Approach

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems