Status
Conditions
Treatments
About
This is a multi-centre, prospective randomised double-blinded cross over study, recruiting a sub-population of patients with heart failure.
All patients will be implanted with a CRT (Cardiac Resynchronisation Therapy) pacemaker with one of the leads positioned on the His bundle in order to obtain direct His-bundle capture. There will be a 2-month run-in period where the device is not active.
A double-blinded cross-over design will then be employed to investigate the effect of His bundle pacing. Patients will be allocated in random order to six month treatment periods in each of the following two states (1) No pacing; (2) AV optimised direct His-bundle pacing. Endpoint measurements will be taken at baseline, 6 months and 12 months post randomisation. Treatment allocation will be blinded to the endpoint assessor and the patient.
126 patients will be needed to detect the expected effect size on the primary endpoint with 90% power. A total of 160 patients will be recruited to allow for patient drop-out.
Full description
Patients entering the study will attend for implantation of a CRT pacemaker device with one lead positioned on the His bundle. This will be performed either at the patient's local hospital or at Imperial College NHS healthcare Trust, no later than 4 months after the patient's screening visit.
All patients will be implanted with a Pacemaker or Implantable cardioverter defibrillator (ICD). In all patients a pacing lead will be positioned in the right atrium (typically the right atrial appendage). All patients will have a pacemaker lead positioned on the His bundle in order to obtain direct His-bundle capture. If it is not possible to successfully implant a His-bundle lead with selective direct His bundle capture or non-selective capture with < 40ms prolongation of the QRS duration, then a lead will be implanted in a lateral branch of the coronary sinus.
In patients who do not have an indication for an Implantable cardioverter defibrillator (ICD) a second ventricular lead will be implanted in a lateral branch of the coronary sinus. If direct His pacing has not been successfully achieved then a further lead will be positioned at the RV apex. In patients who do have an indication for an Implantable cardioverter defibrillator the ICD lead will be positioned in the right ventricle (either RV apex or RV septum).
AV delay optimisation will be performed using acute non-invasive blood pressure acquired using the Finometer device (Finapres Medical systems, Netherlands). The BHF (British Heart Foundation) alternation protocol will be used in order to minimise the effect of background noise.
After implantation of the device there will be a 2 month run-in period prior to randomisation, the device will be programmed not to deliver His bundle pacing therapy during this period.(Back up only pacing and defibrillator function will be enabled).
Two months after patients are implanted with their device, patients will be randomised to either receive active pacing treatment or back up only pacing (pacemaker programmed to VVI 30 bpm). After a further 6 months they will be crossed over to the alternative treatment arm. Treatment allocation will be obtained using an Interactive Web Response System (IWRS) programmed with a randomisation schedule provided by the trial statistician. Appropriate blocking will be used.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
198 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources