ClinicalTrials.Veeva

Menu

The His Optimised Pacing Evaluated for Heart Failure Trial (HOPE-HF).

Imperial College London logo

Imperial College London

Status

Completed

Conditions

Heart Failure

Treatments

Device: Pacemaker: AV optimised, His pacing.

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT02671903
15HH2828

Details and patient eligibility

About

This is a multi-centre, prospective randomised double-blinded cross over study, recruiting a sub-population of patients with heart failure.

All patients will be implanted with a CRT (Cardiac Resynchronisation Therapy) pacemaker with one of the leads positioned on the His bundle in order to obtain direct His-bundle capture. There will be a 2-month run-in period where the device is not active.

A double-blinded cross-over design will then be employed to investigate the effect of His bundle pacing. Patients will be allocated in random order to six month treatment periods in each of the following two states (1) No pacing; (2) AV optimised direct His-bundle pacing. Endpoint measurements will be taken at baseline, 6 months and 12 months post randomisation. Treatment allocation will be blinded to the endpoint assessor and the patient.

126 patients will be needed to detect the expected effect size on the primary endpoint with 90% power. A total of 160 patients will be recruited to allow for patient drop-out.

Full description

Patients entering the study will attend for implantation of a CRT pacemaker device with one lead positioned on the His bundle. This will be performed either at the patient's local hospital or at Imperial College NHS healthcare Trust, no later than 4 months after the patient's screening visit.

All patients will be implanted with a Pacemaker or Implantable cardioverter defibrillator (ICD). In all patients a pacing lead will be positioned in the right atrium (typically the right atrial appendage). All patients will have a pacemaker lead positioned on the His bundle in order to obtain direct His-bundle capture. If it is not possible to successfully implant a His-bundle lead with selective direct His bundle capture or non-selective capture with < 40ms prolongation of the QRS duration, then a lead will be implanted in a lateral branch of the coronary sinus.

In patients who do not have an indication for an Implantable cardioverter defibrillator (ICD) a second ventricular lead will be implanted in a lateral branch of the coronary sinus. If direct His pacing has not been successfully achieved then a further lead will be positioned at the RV apex. In patients who do have an indication for an Implantable cardioverter defibrillator the ICD lead will be positioned in the right ventricle (either RV apex or RV septum).

AV delay optimisation will be performed using acute non-invasive blood pressure acquired using the Finometer device (Finapres Medical systems, Netherlands). The BHF (British Heart Foundation) alternation protocol will be used in order to minimise the effect of background noise.

After implantation of the device there will be a 2 month run-in period prior to randomisation, the device will be programmed not to deliver His bundle pacing therapy during this period.(Back up only pacing and defibrillator function will be enabled).

Two months after patients are implanted with their device, patients will be randomised to either receive active pacing treatment or back up only pacing (pacemaker programmed to VVI 30 bpm). After a further 6 months they will be crossed over to the alternative treatment arm. Treatment allocation will be obtained using an Interactive Web Response System (IWRS) programmed with a randomisation schedule provided by the trial statistician. Appropriate blocking will be used.

Enrollment

198 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Aged 18 or above
  • Ventricular Ejection Fraction (EF) < 40%; BNP needs to be ≥250ng/L for patients with EF 36-40%
  • New York Heart Association (NYHA) class II-IV
  • PR interval ≥200ms
  • Narrow QRS duration (≤140ms) or prolonged QRS duration with typical Right Bundle Branch Block (RBBB) morphology on 12 lead ECG and sinus rhythm

Exclusion criteria

  • Permanent or persistent atrial fibrillation (AF)
  • Paroxysmal atrial fibrillation with history of sustained AF (more than 24 hours) in the 6 months prior to screening
  • Patients who are unable to perform cardiopulmonary exercise testing
  • Other serious medical condition with life expectancy of less than 1 year
  • Lack of capacity to consent
  • Pregnancy
  • Contraindication to use of the relevant study device or leads (as per current manuals from manufacturer)

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Double Blind

198 participants in 2 patient groups

Pacemaker: AV optimised, His pacing
Active Comparator group
Description:
Subjects will remain in this arm for 6 months before being crossed-over. See below intervention details.
Treatment:
Device: Pacemaker: AV optimised, His pacing.
No pacing
No Intervention group
Description:
Subjects will remain in this arm for 6 months before being crossed-over. The pacemaker will be programmed to VVI 30 bpm. Dynamic AV delay will be programmed off throughout the study.

Trial documents
2

Trial contacts and locations

15

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems