Through this study the investigators aim to clarify the relationship between trans-diaphragmatic pressure and various parameters of the diaphragmatic contraction evaluated by ultrasound. Moreover, a lung ultrasound exam will be performed at the end of spontaneous breathing, resistive breathing and maximal inspiratory pressure maneuver (MIP) in order to assess with the use of B-lines for extravascular lung water (EVLW). The following parameters will be studied: esophageal pressure, gastric pressure, diaphragm thickness at peak inspiration (Tdi,pi), diaphragm thickness at end expiration (Tdi,ee), diaphragm thickening (Tdi,pi - Tdi,ee), diaphragm thickness fraction [TFdi=(Tdi,pi - Tdi,ee)/Tdi,ee], diaphragm excursion (Dec), Maximal Inspiratory pressure (M.I.P), Pressure-Time product of the esophageal pressure (PΤPes),Tension Time Diaphragm Index (T.T.Di) and the rapid shallow breathing index (R.S.B.I.). These measurements will be made in two phases.Firstly, during the spontaneous breathing trial and secondly during spontaneous breathing through an airway of reduced diameter.Furthermore, during the M.I.P. test the aforementioned ultrasound parameters will be measured. The aim of this study is to discover new means of a successful prediction of weaning in the first 48 hours following extubation.
Full description
Protocol
The patients will enter a Spontaneous Breathing Trial (S.B.T.) for sixty minutes. During the S.B.T. the desirable measurements will be made: transdiaphragmatic pressure, diaphragm thickening, Tdi,pi , Tdi,ee , TFdi, Di,e, Maximal Inspiratory Pressure (M.I.P.) , Rapid Shallow Breathing Index (R.S.B.I.). If the S.B.T. is successful then the patient will be removed from the mechanical ventilator. For the next 48 hours the patient will be monitored for distress signs and thus be reintubated or if the weaning of the patient was successful extubation.
Flow chart of the study
Definitions
Transdiaphragmatic pressure
Pdi will be measured with the use of a nasogastric catheter which has 2 balloons attached at 25 cm and 10 cm from it's distal end. The balloons, of 7 cm length, will be connected with a pressure transducer and with the use of a linear pneumotachometer Hans Rudolph RSS 100HR the graphic representation of the pressures will be displayed in a computer monitor. The balloons will contain 0,5-1 ml of air and will be placed in the stomach and the lower third of the esophagus. To ensure the correct positioning of the balloons an occlusion test (Baydur test) will be performed ,where the similar fluctuations between the esophageal and the airway pressure will be affirmative. As long as the stomach balloon is concerned the positive pressures during the inspiration will be affirmative of the correct positioning.
Tension Time Diaphragm Index
Ttdi is used as an index of diaphragmatic exhaustion. Measurements above 0,15 are indicative of the diaphragmatic incapability to maintain spontaneous breathing for more than 45 minutes, whence the naming of Ttdi critical
Ttdi = (Pdi/Pdi,max)x(TixTtot)
Rapid Shallow Breathing Index
Rapid Shallow Breathing Index (R.S.B.I.) is a method used for predicting the weaning outcome. It is measured during spontaneous breathing and equates to the ratio of respiratory rate per minute (RR) to the tidal volume (Vt) expressed in liters.
R.S.B.I. = RR/Vt
It has been shown that an R.S.B.I. values below 105 breaths/min/L can predict a successful weaning.
Maximal Inspiratory Pressure
Maximal Inspiratory Pressure (M.I.P.) is used as a predictive factor of the weaning outcome. It is measured with a manometer placed in a fully occluded airway, while the patient tries to breathe through it for 20 seconds. The highest pressure value is named M.I.P. It has been shown that values below -25 cmH2O are indicative of a positive weaning outcome.
Pressure-Time Product of the Esophageal pressure
PTPes was calculated as the area enclosed within the Pes trace, the superimposed recoil of the chest wall and onset and end of inspiratory flow. The chest wall recoil pressure was calculated as 4% of predicted vital capacity.
Diaphragm Ultrasound
The diaphragmatic function is assessed during spontaneous breathing and during breathing with an airway of reduced diameter. The diaphragmatic movement is assessed with ultrasound (Phillips iE33) using a Linear 3-11 MHz head. The ultrasound probe is placed in the mid axillary line perpendicular to the zone of apposition between the 8th-10th intercostal spaces. In this position, the diaphragm is shown as a non-echogenic layer between two echogenic layers which represent the diaphragmatic pleura and the abdominal peritoneum. With this technique the diaphragmatic thickening (Tdi,pi - Tdi,ee), diaphragmatic thickness at end-expiration (Tdi,ee) and end-inspiration (Tdi,pi), diaphragmatic excursion Di,e and diaphragmatic thickening fraction TFdi are measured. All the measurements are made using M-Mode Sonography.
Lung Ultrasound
Lung ultrasound (LUS) was performed in the anterior chest to estimate the number of B-Lines at the end of each phase. A restrictive two-region LUS test, conducted in the anterior chest region, was considered to assess EVLW during these maneuvers. Lung ultrasound was conducted at the end of SBT, MIP and RBT to evaluate for the generation of B-lines during each of these phases. Afterwards patients were categorized, according to the number of B-lines present, in four categories depending on the total number of B-lines 0: 0 B-lines, 1: 1-2 B-lines, 2: 3-7 B-lines, 3: >7 B-lines.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Patients meeting the following standards.
Respiratory Criteria
Cardiovascular Criteria
Adequate level of consciousness
o Glasgow Coma Scale (GCS ≥ 13)
Absence of other reversible comorbidities