Background: Uricemia dramatically rises with the stage of chronic kidney disease (CKD) and correlates with its mortality. Hemodialysis (HD) being the most used treatment at the end stage kidney disease in Sohag governorate , we sought to evaluate its efficacy on the clearance of uric acid (UAc) when used alone and twice per week.
Methods: A cross-sectional study of all consenting patients with CKD stage 5 recruited at random during hemodialysis sessions at hemodialysis unit in Sohag university hospital from July to December 2025. We collected socio-demographic data, relevant clinical information, hemodialysis related variables, and measured serum uric acid (SUA) levels before and after the dialysis to assess the uric acid clearance. A clearance between 65 and 80% and above 80% was considered as low and good efficacy of hemodialysis respectively
Full description
Aim of the the work The aim of this study is to estimate the efficacy of Hemodialysis alone for uric acid clearance in patients on hemodialysis. In order to evaluate the need of adjuvant uric acid lowering therapy
Patients And Methods
Type of The study:
Prospective cross-sectional study.
Place of the study:
Sohag University Hospital, department of Internal Medicine and hemodialysis unit.
Ethical aspect:
Informed Written consent will be taken from all patients to include their data in the study, the research will be approved by medical ethics committee of Faculty of Medicine, Sohag university
Patients:
Inclusion criteria:
• We included all consenting adults aged 18 or older, on maintenance hemodialysis for at least 3 consecutive months receiving 2 to 3 sessions weekly.
Exclusion criteria:
Number of Patients:
The study will include 100 hemodialysis patients for duration of 6 months.
* Methods We carried out a prospective cross-sectional study at the Hemodialysis unit in Sohag University Hospital . Patients included in the study dialyzed with the Fresenius® 4008S generator (Fresenius Medical Care, St. Wendel, Germany) dialyzers , with a polysulfone synthetic dialysis membrane and bicarbonate dialysate.
The size of the dialysis membrane was estimated according to the total body surface of the patient . Membranes sizes FX60 were used for a body surface of approximately (1.2-1.5 m2 ) ; whereas FX80 between (1.6 and 1.8m2 ) and FX100 were used for body surfaces above 1.8m2.
Dialysis adequacy was calculated from the formula Kt/ V urea; K being the clearance of urea given by the dialyzer, t the duration of the dialysis session (4 h) and V the distribution volume of urea [10].
Uric acid clearance (UAc) was estimated using the formula: UAc=100 x (SUA levels before HD-SUA levels after HD) / SUA levels before HD] [14]. We defined two thresholds values for UAc (65 and 80%).
A Hemodialysis session was considered to be of low efficacy if below 65% of reduction, moderate efficacy between 65 and 80% and a good efficacy above 80% of UAc . [15].
These predictors will be included:
Statistical analysis
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria