Thoracoscopic Versus Endocardial Ablation in Patient With Paroxysmal AF After Failed Initial Endocardial Ablation

M

Meshalkin Research Institute of Pathology of Circulation

Status and phase

Completed
Phase 2

Conditions

Paroxysmal Atrial Fibrillation

Treatments

Procedure: Endocardial catheter ablation
Device: Implantable loop recorder
Procedure: Thoracoscopic epicardial ablation

Study type

Interventional

Funder types

NETWORK

Identifiers

NCT01794416
TA-EA-001

Details and patient eligibility

About

The investigators aimed to compare two approaches thoracoscopic epicardial ablation and endocardial catheter ablation after failed initial catheter ablation in patients with paroxysmal atrial fibrillation.

Enrollment

50 patients

Sex

All

Ages

18 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • failed initial catheter ablation
  • paroxysmal atrial fibrillation

Exclusion criteria

  • chronic lung disease
  • body mass index >35
  • longstanding atrial fibrillation 1 year
  • previous stroke or transient ischemic attack
  • left atrial thrombus
  • left atrial size >65 mm
  • left ventricular ejection fraction <35%

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

50 participants in 2 patient groups

Thoracoscopic epicardial ablation
Active Comparator group
Description:
Patients were treated with video-assisted thoracoscopy under general anesthesia. PVI was performed from the epicardial side with a bipolar RF ablation clamp (AtriCure). At least 2 overlapping applications around each of the ipsilateral veins were made, and isolation was confirmed by the absence of PV potentials and exit block during pacing. An additional application was made in the interatrial Waterston groove in the right side to isolate the ganglionic plexi from the atria. On the left side, the ligament of Marshal was cut, but no additional ablation of ganglionic plexi was pursued. The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.
Treatment:
Procedure: Thoracoscopic epicardial ablation
Device: Implantable loop recorder
Endocardial catheter ablation
Active Comparator group
Description:
Externally-irrigated tip (5-mm tip, Celsius Thermo-Cool, Biosense Webster, Diamond Bar, CA, USA). Temperature-controlled RF delivery was performed with a maximum power output of 50 W and temperature limit of 50 C. The catheter was irrigated using 0.9% saline infusion at a flow rate of 20-40 mL/min during RF delivery and 2 mL/min between applications using a commercially available pump (Cool Flow, Biosense Webster). The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.
Treatment:
Procedure: Endocardial catheter ablation
Device: Implantable loop recorder