ClinicalTrials.Veeva

Menu

Timely Acquirement of 12-lead ECG Using Patchy-type Wireless Device Among Patient With Chest Pain

Samsung Medical Center logo

Samsung Medical Center

Status

Completed

Conditions

Electrocardiography
Chest Pain

Treatments

Device: patchy-type wireless 12-lead ECG

Study type

Interventional

Funder types

Other

Identifiers

NCT04048733
2019-01-046

Details and patient eligibility

About

In this study, the investigators compare timely acquirement of 12-lead ECG using patchy-type wireless versus using standard 12-lead ECG system among patient with chest pain in ED. The purpose of this study is to determine the difference of timely acquirement of 12-lead ECG using two different systems and the difference of hospital delay in ED between two groups. The participants were randomly divided into 2 groups: one performing an ECG examination using the standard 12-lead ECG and the other using the patch-type mobile 12-lead ECG.The 12-lead ECG will be taken 2 times serially in every 15 minutes.

Full description

  1. research background Electrocardiography (ECG) is the most important diagnostic tool for rapid detection of acute coronary syndrome, and should be performed and interpreted promptly on appearance of symptoms. Early detection of ST-elevation myocardial infarction (STEMI) on a 12-lead ECG, within 10 minutes after the first medical contact before hospitalization not only minimizes the time taken for diagnosis and reperfusion therapy but also increases the chances of patient survival and preservation of myocardial function.

    However, it is challenging to perform a 12-lead ECG promptly using the standard 12-lead ECG system for several reasons. First, it is difficult to identify the landmarks for the 10-electrode configuration of the standard ECG. Second, electrodes on the extremities often cause artifacts due to body and muscle movements. Moreover, most of the standard 12-lead ECG systems have cables connected to the precordial and limb leads, which frequently get entangled and disorganized, and can be difficult to manage.Most importantly, its accuracy is dependent on the operators' experience; not just that of the nurses or emergency medical technicians, but also of cardiologists.These difficulties might increase the time taken to perform an ECG especially in pre-hospital situations.

  2. Objective The purpose of this study is to determine the difference of timely acquirement of 12-lead ECG using two different systems and the difference of hospital delay in ED between two groups.

  3. Design : Randomized controlled trial

  4. Setting : ED at the Samsung medical center

  5. Enrollment : 36 patients who visited the ED with chest pain

  6. Intervention Standard 12-lead ECG will be performed at the time of visiting ED to the participants with chest pain.

ED physicians will prescribe to perform second and third 12-lead ECG in every 15 minutes.

  1. Control group : Second and third 12 lead ECG will be taken using standard 12-lead ECG device as a doctor's order.

  2. Study group :Second and third 12 lead ECG will be taken using patchy-type 12-lead ECG device as a doctor's order.

  3. scoring To measure, interval from the anticipated time to take 12-lead ECG to the time actually performed will be measured. The duration from the anticipated time to the time of verification by physician will be also measured.

  4. study period The experiment ends when patient who agreed to participate in the study discharged the ED.

Enrollment

36 patients

Sex

All

Ages

19+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • A subject who visited the ER with a cardiogenic chest pain
  • adult patients over 19 years of age
  • A subject who completed the 1st ECG

Exclusion criteria

  • A subject who did not agree with this study
  • arrest patient
  • Dead on arrival
  • STEMI patients who confirmed by 1st ECG in ER
  • shock status patient in triage state

Trial design

Primary purpose

Other

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

36 participants in 2 patient groups

Patchy type-lead ECG
Experimental group
Description:
ED physicians will prescribe to perform second and third 12-lead ECG in every 15 minutes. Second and third 12 lead ECG will be taken using patchy-type 12-lead ECG device as a doctor's order. This device will be automatically record 12-lead ECG 3 times in 1 minutes at a time by its algorithm.
Treatment:
Device: patchy-type wireless 12-lead ECG
Standard 12-lead ECG
No Intervention group
Description:
ED physicians will prescribe to perform second and third 12-lead ECG in every 15 minutes. Second and third 12 lead ECG will be taken using standard 12-lead ECG device as a doctor's order. Interns and ECG technicians will perform 12-lead ECG as they perform as usual.

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location