Timely Acquirement of 12-lead ECG Using Patchy-type Wireless Device by Emergency Medical Technician in Ambulance

Samsung Medical Center logo

Samsung Medical Center

Status

Completed

Conditions

Electrocardiography
Chest Pain

Treatments

Device: patchy-type wireless ECG
Device: defibrillator ECG

Study type

Interventional

Funder types

Other

Identifiers

NCT04114760
2019-04-004

Details and patient eligibility

About

In this study, the investigators compare timely acquirement and effectiveness of 12-lead ECG using patchy-type wireless versus using defibrillator which contain ECG examination function in ambulance.

The purpose of this study is to determine the difference of timely acquirement of 12-lead ECG using two different systems and the difference of efficiency of ECG examination in ambulance between two groups.

The participants in this simulation study were divided randomly into 2 groups :

Group A is performing an ECG examination on mock patient using defibrillator which contained 12-lead ECG checking function. And take a 15 minutes wash out period. After the wash out period, group A subject performing an ECG examination using patchy-type wireless device.

Group B subject is performing an ECG examination on mock patient using patchy-type wireless device first, and take a 15 minutes wash out period. After the wash out period, group B performing an ECG examination using defibrillator which contain 12-lead ECG function.

Both group's ECG examination is performing in the ambulance.

Enrollment

24 patients

Sex

All

Ages

19 to 65 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Who have a certification of Emergency Medical Technician in korea and have a nurse license in korea.
  • who currently engaged of emergency medical dispatch.

Exclusion criteria

  • A subject who did not agree with this study

Trial design

Primary purpose

Other

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

24 participants in 2 patient groups

Group A : defibrillator ECG to patchy-type ECG
Active Comparator group
Description:
Group A subject will performing ECG examination to a mock patient in the ambulance. First ECG performance will be using defibrillator which contain 12-lead ECG checking function. And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using patchy-type wireless device. when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect.
Treatment:
Device: defibrillator ECG
Group B : patchy-type ECG to defibrillator ECG
Experimental group
Description:
Group B subject will performing ECG examination to a mock patient in the ambulance. First ECG performance will be using patchy-type wireless device. And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using defibrillator which contain 12-lead ECG checking function. when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect.
Treatment:
Device: patchy-type wireless ECG