ClinicalTrials.Veeva

Menu

Tissue Doppler Imaging (TDI) Versus Electrocardiography (ECG) Interventricular Pacing Delay Optimization in Cardiac Resynchronization Therapy (CRT)

H

Hospital Clinic of Barcelona

Status and phase

Completed
Phase 3

Conditions

Cardiac Resynchronization Therapy
Heart Failure

Treatments

Device: Electrocardiographic optimization of the interventricular pacing delay according to QRS width
Device: Interventricular pacing delay optimization by using Tissue Doppler-derived displacement curves

Study type

Interventional

Funder types

Other

Identifiers

NCT01179997
CRT-opt

Details and patient eligibility

About

The aim of this study was to compare the response to cardiac resynchronization therapy when the interventricular pacing interval was optimized by Tissue Doppler Imaging (TDI) to response when it was optimized following QRS width criteria.

Enrollment

156 patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients submitted to de novo implant due to conventional cardiac resynchronization therapy indications.

Exclusion criteria

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Quadruple Blind

156 participants in 2 patient groups

Tissue Doppler Imaging (TDI) optimization
Active Comparator group
Description:
Interventricular pacing delay optimized according to Tissue-Doppler echocardiography
Treatment:
Device: Interventricular pacing delay optimization by using Tissue Doppler-derived displacement curves
Electrocardiographic optimization
Active Comparator group
Description:
Interventricular pacing delay optimized according to QRS width observation in the 12-lead surface electrocardiogram
Treatment:
Device: Electrocardiographic optimization of the interventricular pacing delay according to QRS width