Incorporating wire threaded custom tunnel attachments with clear aligner therapy is a novel approach developed to address the shortcomings of the currently available orthodontic systems. This hybrid system is anticipated to take advantage of the benefits and overcome many of the limitations of traditional fixed buccal/lingual appliances and clear aligner therapy. The concept utilizes light arch wires to be threaded through computer designed, chairside-fabricated composite tunnel attachments to achieve better control of three-dimensional tooth movements not achievable by clear aligners, such as Invisalign® (Align Technology, Santa Clara, CA) alone. The superelastic feature of the arch wires allows delivery of more continuous forces than aligners alone, potentially permitting shorter duration of recommended aligner wear during orthodontic treatment. A virtual set-up would be used to plan the desired position of the teeth, which in turn will be used to customize the size and position of composite tunnel attachments based on how two round arch wires will pass through tubes within the attachments. The attachments can be placed on either the buccal or lingual surfaces of teeth, depending on clinical preferences and esthetic demands. This is achievable using in-house aligners, which will also allow the fabrication of aligners in the office or at a conventional orthodontic lab at a fraction of the cost of traditional clear aligners.
Full description
Specific aims:
Test and formally describe a novel method that utilizes clear aligners paired with computer-designed, chairside-fabricated tunnel attachments to achieve tooth movements that are challenging for clear aligners.
Conduct a randomized clinical trial to compare the ability of a traditional clear aligner system Invisalign® (Align Technology, Santa Clara, CA) and a clear aligner system incorporating wire threaded tunnel attachments in:
Materials and Methods:
A virtual set-up is completed by the clinician to plan the position, orientation, and dimension will be customized on the teeth to be moved.Generally, they are spherically shaped and their dimensions are approximately 2-3 mm. Vacuum-formed attachment template will be made to take the shape of a tube-holding spheres, in which tubes are embedded. The tubes are standard in size with an outside diameter of 0.032", and an inside diameter of 0.019" and 2 mm length The template will be loaded with composite after inserting the metal tubes are placed in their predetermined location on the tray. Double tubes will be used when torque control is needed. 0.016" buccal or lingual round wires will be placed into the tunnel attachments along the attachments. Aligners will be delivered to patient to be worn for at least 8 hours a day and changed as determined by the Dental Monitoring application.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
34 participants in 2 patient groups