About

Prospective validation of the ultrasound-assessed internal jugular vein distensibility (JVD) ratio to identify patients with systolic chronic heart failure and right atrial pressure (RAP) of 7 or less mmHg measured by the right heart catheterization. In a calibration cohort, a threshold ratio will be identified, above which the RAP is normal with the highest accuracy. This diagnostic tool with a defined threshold of the JVD ratio will be assessed in a second prospective validation cohort.

Full description

Peripheral congestion is caused by an excess of fluid in tissues and vessels. Fluid overload is associated with poor outcome in heart failure (HF)(1). Several clinical signs can suggest peripheral congestion, such as peripheral edema or neck vein distention. In particular, the clinical sign of the neck jugular vein distention is used to estimate right atrial pressure (RHC) and is associated with fluid overload and congestion. Nevertheless, clinical assessment is somewhat subjective depending on the anatomy of the patient's neck and on the expertise of the physician (2). It has been reported that the detection of elevated RAP can be measured using a bedside ultrasound (US)(3). In this study, the Authors compared the jugular vein distensibility (IVD) ratio assessed with US with the invasive measure of the RAP reporting a good accuracy in detecting normal RAP. They showed a good performance of this diagnostic test, nevertheless, they evaluated this diagnostic test in a mix population including only 27 patients with congestive HF. More recent studies showed the prognostic value of the IVD ratio in patients with HF (4). Nevertheless, a specific threshold of the internal JVD ratio to identify patients with normal RAP in the setting of patients with systolic chronic HF (CHF) has never been described. Furthermore, in patients with CHF clinical signs of congestion cannot always be evident at clinical examination, making the decision to modify diuretic dosage or to introduce vasodilator drugs uneasy. Thus, a convenient, accurate, and reproducible non-invasive tool to identify patients with normal RAP (normal mean RAP is 7 or less mmHg) patients with systolic CHF would be desirable to tailor therapy, in particular in outpatient clinics.

The main hypothesis of this study is that US-assessment of the internal JVD could be an accurate diagnostic tool to identify patients with normal RAP in this challenging set of patients.

The primary aim of the study prospectively validates an US-assessed internal JVD ratio to identify patients with systolic CHF and RAP of 7 or less mmHg measured by RHC. In a calibration cohort, a threshold of the JVD ratio above which the RAP is normal with the highest accuracy will be identified and then this diagnostic tool with a defined JVD ratio will be validated in a second prospective validation cohort.

Enrollment

200 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • All patients with systolic chronic heart failure defined by a left ventricular ejection fraction (LVEF) <50% on echocardiogram that, undergo elective RHC in the heart transplant/left ventricular assist device work-up.
  • In case of occlusion of the left internal jugular vein (IJV), the RHC is performed from to contralateral IJV, and US-assessed JVD ratio will be measured on the right IJV.

Exclusion criteria

  • Patients supported by a left ventricular assist device.
  • Patients with acute heart failure that undergo RHC as an urgent procedure in hemodynamically unstable patients.
  • Patients unable/unwilling to sign a written informed consent.
  • Patients in which an RHC is not feasible from an internal jugular vein.

Trial design

200 participants in 2 patient groups

Calibration group
Description:
Patients with systolic chronic heart failure who undergo right heart catheterization (RHC) for heart transplant/left ventricular assist device workup.
Treatment:
Diagnostic Test: Linear ultrasound (US) assessment of the internal jugular vein
Validation group
Description:
Patients with systolic chronic heart failure who undergo RHC for heart transplant/left ventricular assist device workup.
Treatment:
Diagnostic Test: Linear ultrasound (US) assessment of the internal jugular vein