Adult patients (>18 years) with newly diagnosis of Ph negative myeloproliferative neoplasms (MPNs) according to WHO 2016 criteria, will be recruited to this study.
This study is the result of the collaboration the Hematology Division of Federico II University Medical School of Naples (Italy), that performed the US investigation and the IRCCS SYNLAB SDN where the patients carried out MR. The study is conducted in accordance with the Declaration of Helsinki. All subjects gave informed consent to receive both US and MR scans of the spleen.
All spleen US scans were performed by the same operator (with>10 years of experience in abdominal US), who used an EPIQ 5 Philips instrument with a 1-5 MHz broadband curvilinear probe. The spleen was scanned in patients who were fasting, in the longitudinal and transverse planes by using an intercostal approach, a subcostal approach, or both.
The patient was placed in a supine or right-sided position until complete organ visualization was achieved. Perimeter, longitudinal diameter (LD), and area, defined as the maximum measurements with splenic borders and angles clearly defined, were measured, and SV (in milliliters) was calculated automatically. For each subject, the mean value of 3 measurements repeated on the same imaging session was calculated and recorded for final analysis. Within two weeks from the US, each patient underwent an MRI of the upper abdomen to evaluate the splenic volume. MRI examinations were performed using a 3T Biograph mMR scanner (Siemens Healthcare, Erlangen, Germany) with 4-channel flex phased-array body coil. Routine clinical abdominal MRI acquisition includes coronal T2W Half-Fourier Acquisition Single-shot Turbo spin Echo imaging (HASTE), axial T1 Dual-echo FSE, axial T2 TSE Fat Sat, and an axial diffusion-weighted imaging (DWI). The DWI includes an apparent diffusion coefficient (ADC) map that was automatically generated at the time of acquisition. At last, an isotropic 2mm3 axial Volumetric Interpolated Breath-hold Examination (VIBE) sequence for SV evaluation was acquired. For the latter, attention was paid to optimize the field of view to the spleen, in order to reduce patient's apnea and possible respiratory artifacts. A radiologist with mote than 10 years of experience in abdominal MRI reporting performed measurement of the three orthogonal diameters of the spleen for each patient. Subsequently, SV was calculated using ITK-SNAP software and semi-automatic 3D segmentation approach, firstly based on a signal threshold.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal