ClinicalTrials.Veeva

Menu

Use of Prineo in Breast Reduction Surgery

Columbia University logo

Columbia University

Status

Completed

Conditions

Post-operative Scar
Efficiency of Surgical Incision Closure

Treatments

Device: Prineo

Study type

Interventional

Funder types

Other
Industry

Identifiers

NCT01996917
AAAM2053

Details and patient eligibility

About

This is a prospective, randomized, controlled, single-blinded study to compare Prineo™ with subcuticular sutures in 20 women undergoing bilateral breast reduction. For each patient, the final skin layer of one breast will be closed with subcuticular suture while the other breast will be closed with Prineo™. The treatment will be randomized to left or right breast. Therefore, the investigators will have 20 breasts in the suture group and 20 in the Prineo™ group, with each patient serving as her own control. For this study, the resident will close one side with suture and Dr. Rohde will apply the Prineo. The investigators will perform this study of incision closure under conditions as similar to normal conditions of closure.

Full description

Wound closure with dermal sutures is time consuming and may increase risk of infection and inflammation. Moreover, appearance of the resulting scar depends largely on surgeon technique. Use of the Prineo™ wound closure system may decrease operative time, decrease incidence of infection and inflammation, and improve aesthetics of the resulting scar. Prineo™ has been shown to hold as well as sutures for the first 12-25 days and may reduce closure time of the final skin layer up to 75% in abdominoplasty and breast procedures. The system provides excellent coverage of the wound edge, protecting the incision with a microbial barrier. Cosmetic results in abdominoplasty and breast procedures appear to be equivalent to sutures.

The main endpoints will be operative time to closure of the final skin layer and patient-rated and blinded observer-rated scar quality. The investigators hypothesize that operative time to closure of the final skin layer using Prineo™ will be faster than operative time to closure using subcuticular suture. The investigators also hypothesize that subjective and objective scar quality of incisions closed with Prineo™ will be better than those closed with subcuticular suture.

Enrollment

21 patients

Sex

Female

Ages

18 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Women undergoing Wise pattern breast reductions for symptomatic macromastia.

Exclusion criteria

  • Subjects who have an allergy to cyanoacrylate, formaldehyde, surgical tape, or any other known component of the Prineo system will be excluded.
  • Subjects who refuse to be photographed or refuse to have their scars assessed by a blinded plastic surgeon will be excluded.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

21 participants in 2 patient groups

Prineo closure
Active Comparator group
Description:
One breast will have skin closure with Prineo.
Treatment:
Device: Prineo
Standard Suture
No Intervention group
Description:
One breast will be closed in the standard fashion with suture.

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems