ClinicalTrials.Veeva

Menu

Use of Superparamagnetic Iron Oxide (SPIO) in Sentinel Lymph Node Detection for Breast Cancer

The University of Hong Kong (HKU) logo

The University of Hong Kong (HKU)

Status

Active, not recruiting

Conditions

Sentinel Lymph Node
Breast Cancer

Treatments

Procedure: sentinel lymph node biopsy procedure

Study type

Interventional

Funder types

Other

Identifiers

NCT05288686
HKUCTR-2709

Details and patient eligibility

About

Sentinel lymph node biopsy is mandatory during breast cancer operation for disease staging and treatment. The localization of sentinel lymph node is by the injection of radioisotope and blue dye, which is the gold standard. However the use of radioisotope and blue dye are associated with specific drawbacks. Superparamagnetic iron oxide is a magnetic tracer which is FDA-approved for sentinel lymph node localization. The hypothesis of this study is superparamagnetic iron oxide can replace the conventional dual mapping of radioisotope and blue dye in the detection of sentinel lymph nodes for early breast cancers.

Full description

Sentinel lymph node biopsy has replaced axillary dissection as the standard of care in clinically node negative breast cancer. Lymphatic mapping with radioisotope and blue dye were most studied tracer agents and their combination was shown to give the highest nodal identification rate and lowest false negative rate. However the use of radioisotope is strictly monitored due to its radioactivity and blue dye is associated with potential allergic reactions and skin tattoo. Superparamagnetic iron oxide is non-radioactive. It gives an audible signal with the magnetometer and a brown color as visual cue. It has demonstrated comparable nodal identification rate with the conventional method in multiple non-inferiority trials in Europe and the USA. There was no randomized controlled trial for a head-to-head comparison between these mapping technique. The hypothesis of this study is superparamagnetic iron oxide alone can replace the conventional dual mapping of radioisotope and blue dye.

Previous literature suggested the nodal detection rate for conventional method and SPIO was around 97%. Assuming a non-inferiorly limit of 5%, with a power of 80% and 5% significance level, the number of patients per treatment arm should be 144. We will need a sample size of 300 patients, taking into account a loss to follow-up of <5%.

All patients recruited will be provided full explanation of the study and written voluntary consents will be obtained before randomization.

All data will be prospectively collected by dedicated research assistant and computerized into a database. All statistical analysis will be performed with Statistical Product and Service Solution (SPSS) version 24. Missing information will be marked and significant missing data will be excluded from analysis. Chi-square test will be used to compare discrete variables and student T test or Mann Whitney U test for continuous variables. P value less than 0.05 will be considered statistically significant.

Personal data will be obtained by principal investigator and dedicated research assistant to allow analysis of the results. These data will be anonymous, only identified by the first three letters of patient's name. The file will be encrypted and stored in the study institution. All the information will be solely for research purpose and kept strictly confidential.

Research subjects will be provided with phone contacts for any questions or emergency related to the study.

Enrollment

282 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • All patients with clinical T1-3N0 invasive ductal carcinoma or invasive lobular carcinoma planned for breast conservative surgery or mastectomy, with sentinel lymph node biopsy
  • Patients planned for upfront operation or neoadjuvant chemotherapy are allowed

Exclusion criteria

  • Patients with hypersensitivity to dextran compounds, iron or blue dye
  • Patients with iron overload disease
  • Pregnant or lactating patients
  • Patients with pacemaker or other implantable metallic devices in chest wall or prosthesis in shoulder
  • Mentally incompetent patients

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

282 participants in 2 patient groups

SPIO arm
Experimental group
Description:
Superparamagnetic iron oxide guided sentinel lymph node mapping
Treatment:
Procedure: sentinel lymph node biopsy procedure
Control arm
Active Comparator group
Description:
Conventional radioisotope and blue dye guided sentinel lymph node mapping
Treatment:
Procedure: sentinel lymph node biopsy procedure

Trial contacts and locations