Using Electrical Bioimpedance Assessments to Estimate Perioperative Total Body Water and Postoperative Fluid Need

U

United States Naval Medical Center, Portsmouth

Status

Completed

Conditions

Gastroesophageal Reflux Disease
Intestinal Cancer
Diverticulitis
Pancreatic Cancer

Treatments

Device: Bodystat Quadscan 4000

Study type

Interventional

Funder types

Other U.S. Federal agency

Identifiers

NCT02200055
CIP# 12-0050

Details and patient eligibility

About

Being able to accurately monitor patient bodily fluid levels during and after surgery is very important, as there are a number of complications that can arise if a patient's fluid levels become unbalanced, such as swelling within or pressure on various bodily organ systems. There are several different ways that physicians can monitor a patient's fluid balance during and after surgery, such as measuring the amount of urine output or the use of central venous catheters which measure the pressure in the veins entering the heart. Most of these techniques are invasive since they require tubes to be inserted into the body. A potential alternative would be to use a noninvasive technique such as electrical bioimpedance (BIA).

Bioimpedance assessments work by using small electrical currents that can accurately predict both the water surrounding the outside of cells in the body, as well as the total amount of water in the entire body. Electrical bioimpedance assessments have been used to estimate patient swelling following surgery (edema), to measure the volume of blood the heart is pumping out, as well as to calculate body fat percentages.

The goal of this study is to relate this technology to fluid shifts within the body that occur as a result of surgery, in particular, major intra-abdominal surgeries. By using bioimpedance during and after surgery, the investigators will compare the data collected with that calculated by using traditional measures of body fluid status, such as urine output and intraoperative blood loss. During the study, the bioimpedance monitors will not replace the standard bodily fluid monitors and will not interfere with their readings. Additionally, the electrical current produced by the bioimpedance monitors is too small for patients to feel and will not interfere with medical devices such as pacemakers.

Full description

Being able to accurately monitor patient bodily fluid levels during and after surgery is very important, as there are a number of complications that can arise if a patient's fluid levels become unbalanced, such as swelling within or pressure on various bodily organ systems. There are several different ways that physicians can monitor a patient's fluid balance during and after surgery, such as measuring the amount of urine output or the use of central venous catheters which measure the pressure in the veins entering the heart. Most of these techniques are invasive since they require tubes to be inserted into the body. A potential alternative would be to use a noninvasive technique such as electrical bioimpedance (BIA).

Bioimpedance assessments work by using small electrical currents that can accurately predict both the water surrounding the outside of cells in the body, as well as the total amount of water in the entire body. Electrical bioimpedance assessments have been used to estimate patient swelling following surgery (edema), to measure the volume of blood the heart is pumping out, as well as to calculate body fat percentages.

The goal of this study is to relate this technology to fluid shifts within the body that occur as a result of surgery, in particular, major intra-abdominal surgeries. By using bioimpedance during and after surgery, the investigators will compare the data collected with that calculated by using traditional measures of body fluid status, such as urine output and intraoperative blood loss. During the study, the bioimpedance monitors will not replace the standard bodily fluid monitors and will not interfere with their readings. Additionally, the electrical current produced by the bioimpedance monitors is too small for patients to feel and will not interfere with medical devices such as pacemakers.

Enrollment

86 patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients having major intra-abdominal procedures under general anesthesia requiring hospitalization postoperatively during the initial recovery from surgery.

Exclusion criteria

  • Patients not having intra-abdominal procedures (ie. Thyroidectomy, open or laparoscopic inguinal hernia repair, excision of skin lesions, breast procedures)
  • Patients having outpatient surgery
  • Patients having laparoscopic cholecystectomies, laparoscopic or open appendectomies
  • Patients having bariatric surgery (because the bioimpedance assessment technology has proven to be unreliable in obese populations)
  • Morbidly obese patients (BMI >40)
  • Unable to provide informed consent
  • Pregnant women

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

86 participants in 1 patient group

Bioimpedance Assessment
Experimental group
Description:
The only group will be those patients having major intra-abdominal surgical procedures. Each patient involved in the study will be evaluated with a bioimpedance monitor ('Bodystat Quadscan 4000') to assess total body water, estimated body water, and intravascular body water volume preoperatively, postoperatively, and daily during the postoperative recovery period. Bioimpedance Assessment
Treatment:
Device: Bodystat Quadscan 4000