Introduction. Skin blood flow (SBF) is crucial for transporting nutrients during healing to treat scarring. Negative pressure therapy (NPT) is a promising option to enhance SBF. However, it is unclear what dosage of NPT is most effective in treating scars.
This study compared NPT dosages of -105 mmHg, -125 mmHg, and -145 mmHg to assess the impact of NPT treatment on SBF in scar tissue and the correlation of NPT. If participants experience any symptoms of discomfort, NPT can be discontinued immediately.
36 scarred subjects were recruited to assess the efficacy of various NPT interventions. SBF applications are defined as perfusion levels instantly affecting NPT, and termination is defined as SBF after NPT.
The study runs from May 11, 2022, to May 11, 2023, at Asia University Hospital.
This study was funded by the National Science and Technology Council, Taiwan (NSTC 112-2221-E-468-004)
The main contact was Chi-Wen Lung, the person in charge of a college or university department of Product Design, Asia University, Taichung 413305, Taiwan.Email address: cwlung@asia.edu.tw
Full description
Introduction. Skin blood flow (SBF) is crucial for transporting nutrients during healing to treat scarring. Negative pressure therapy (NPT) is a promising option to enhance SBF.
This study's hypothesis was that NPT can enhance SBF in scar tissue and that the specific NPT dose affects this effect. The purpose of this study was to confirm the different dosages of NPT applied to scar tissue by comparing the blood flow before and after the effects of different NPT dosages. This will also contribute to the emerging field of scar treatment and provide evidence-based recommendations.
All recruited participants were approached to participate in a research study investigating the effects of NPT in a double-blind, parallel-group study on scar healing. This study used three negative pressure changes at -105, -125 mmHg, and -145 mmHg at 10 min. The suction method created a negative pressure in the cup using an electronic negative-pressure device (Medi Pump TC-2000V; Anest Iwata Sparmax Co., Ltd., Taipei, Taiwan). A cup with an inner diameter of 45 mm and outer diameter of 53 mm was used for cupping therapy. Each side of the cup rim had a width of 4 mm; therefore, no pain was caused by the cup rim.
Pearson product-moment correlation analysis was used to determine the correlations between the SBF-Baseline, SBF-Application, and SBF-Termination factors.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
36 participants in 1 patient group