This study will verify the 1-channel patch-type ECG's arrhythmia diagnostic concordance rate and electrocardiogram measurement performance by collecting ECG signals from patch-type ECG and Holter device simultaneously for data analysis.
Full description
[How to conduct research] This study targeted adults aged 19 years or older. Written consent is obtained from those who are diagnosed with arrhythmia and need a Holter examination among outpatients or inpatients at the Cardiology Department of Kosin University Gospel Hospital. The medical staff attaches the Holter device to the subject and the patch-type electrocardiograph in the Holter examination room. Holter device and patch-type electrocardiograph are returned to the Holter examination room after measuring the electrocardiogram for 24 hours. ECG signals from patch-type electrocardiographs and commercial Holter device and arrhythmia detection information are compared and analyzed.
[Number of Subjects] The number of this study is 105. Written consent is obtained from those who are diagnosed with arrhythmia and need a Holter examination among outpatients or inpatients at the Cardiology Department.
[Data analysis plan] In this study, the personal identification information of the subjects will be coded non-identifying and the collected electrocardiogram data will be stored in the cloud with restricted access from outsiders. Coded, non-identified research data is stored and managed in the cloud in compliance with privacy standards and information security standards. ECG data transmitted through the mobile application is stored in the cloud. Confidentiality and security of data are guaranteed, and data collected from patch-type electrocardiograph is used only for research. The electrocardiogram data acquired in this study are obtained in TXT or MAT format and used for data analysis.
The efficacy evaluation items are as follows.
Comparison of ECG signal concordance
Comparison of the parameters below for a noise-free section of about 1 minute, not the entire section
Comparison of arrhythmia diagnosis concordance rates between 24-hour patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories (total of 19 including ventricular ectopic beat)
The evaluation method and interpretation method are as follows.
In the case of categorical variables, the sensitivity and positive predictive value are evaluated, and in the case of continuous variables, the concordance between the measured values measured by the patch-type electrocardiograph and the Holter device is evaluated using the Bland-Altman plot.
Amplitude difference of P-wave, QRS-complex and T-wave & Correlation to the entire signal
Time difference of P, QRS, T (On/Off time) & PR, QRS, QT (Duration/Interval)
Root Mean Square of Heart Rate
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
105 participants in 1 patient group