ClinicalTrials.Veeva

Menu

VectorFlow Tunneled Dialysis Catheter (TDC) Versus Palindrome TDC

University of Pennsylvania logo

University of Pennsylvania

Status

Completed

Conditions

Renal Failure Chronic Requiring Hemodialysis
Chronic Renal Insufficiency

Treatments

Device: VectorFlow TDC
Device: Palindrome TDC

Study type

Interventional

Funder types

Other
Industry

Identifiers

Details and patient eligibility

About

Randomized two-arm study examining 90 day primary patency of two FDA-approved tunneled dialysis catheters.

Full description

The VectorFlow tunneled dialysis catheter is a novel symmetrical tip design tunneled dialysis catheter which in pre-clinical testing and retrospective review has improved flow and patency compared to other dialysis catheter designs. This study will compare 90 day patency rates of newly inserted VF catheters to the Palindrome catheter both of which are FDA approved devices and will inserted as standard of care. The Palindrome catheter has been selected as the comparison device because it is also a symmetrical tip catheter design and prior studies by the manufacturer of this device suggests it has a lower occlusion rate and better flow compared to other catheter designs.

Enrollment

100 patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • End stage renal disease or acute renal failure requiring hemodialysis through a tunneled dialysis catheter
  • Age >18, Age <80
  • Capable of giving informed consent

Exclusion criteria

  • Coagulopathy defined as international normalized ration (INR) >2 which cannot be corrected with fresh frozen plasma
  • Platelet count <50,000/microliter, which cannot be corrected with platelet transfusion
  • Active skin infections at site of TDC insertion
  • Presence of bacteremia or infected AVG/AVF within 7 days prior to enrollment
  • Neutropenia defined as absolute neutrophil count less then 1,700/microliter
  • Known central venous stenosis
  • Occlusion of bilateral external and internal jugular veins or bilateral brachiocephalic veins or stenosis of the superior vena cava
  • Functioning surgical HD access (ie AVG/AVF) or AVG/AVF which is expected to be functional within 90 days of enrollment
  • Inability to provide informed consent
  • Pregnant or nursing women
  • In the event a physician does not feel that either catheter would be appropriate for a subject, the subject will not be eligible to participate

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Quadruple Blind

100 participants in 2 patient groups

Palindrome TDC
Active Comparator group
Description:
TDC insertion with Palindrome will be in accordance with its FDA-approved indication under moderate sedation or general anesthesia with local anesthesia using 1% lidocaine in per institutional protocol. Following TDC insertion, the catheter may be used immediately. The goal of HD is typically to achieve a target effective blood flow of 300mL/min within the first 3 hemodialysis sessions. The dialysis records from each of the first three HD sessions will be reviewed by the study coordinator for (A) Blood flow rate (QB), (B) Arterial and venous lumen pressures, (C) Kt/V, and (D) Urea reduction ratio (URR). Additionally, need and use of thrombolytic infusion (ie t-PA) (other than single dose injection) to restore or improve patency and/or need for catheter exchange.
Treatment:
Device: Palindrome TDC
VectorFlow TDC
Active Comparator group
Description:
TDC insertion with VectorFlow will be in accordance with its FDA-approved indication under moderate sedation or general anesthesia with local anesthesia using 1% lidocaine in per institutional protocol. Following TDC insertion, the catheter may be used immediately. The goal of HD is typically to achieve a target effective blood flow of 300mL/min within the first 3 hemodialysis sessions. The dialysis records from each of the first three HD sessions will be reviewed by the study coordinator for (A) Blood flow rate (QB), (B) Arterial and venous lumen pressures, (C) Kt/V, and (D) Urea reduction ratio (URR). Additionally, need and use of thrombolytic infusion (ie t-PA) (other than single dose injection) to restore or improve patency and/or need for catheter exchange.
Treatment:
Device: VectorFlow TDC

Trial documents
1

Trial contacts and locations

2

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems