ClinicalTrials.Veeva

Menu

Video- Or Direct Laryngoscopy for Endotracheal Intubation in Newborns (VODE)

University College Dublin logo

University College Dublin

Status

Completed

Conditions

Intubation, Intratracheal
Infant, Newborn
Laryngoscopes

Treatments

Device: Videolaryngoscopy
Device: Direct laryngoscopy

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Endotracheal intubation is a critical intervention for newborn babies. Laryngoscopy is the crucial part of endotracheal intubation. Traditionally, operators use a standard laryngoscope to view the larynx by looking directly into the mouth (direct laryngoscopy). More recently videolaryngoscopes that have a video camera mounted at the tip of the laryngoscope blade have been developed, Rather than look directly into the mouth, the operator looks at a screen that displays the view acquired by the camera (indirect laryngoscopy). Videolaryngoscopes have been demonstrated to be useful for teaching trainees direct laryngoscopy. However, it may be that all clinicians are more successful with a videolaryngoscope. The investigators will compare whether clinicians who are randomly assigned to intubate newborn infants using a videolaryngoscope are more successful in intubating newborn infants at the first attempt compared to clinicians who are randomly assigned to intubate newborn infants using a standard laryngoscope.

Full description

Endotracheal intubation is a critical intervention for newborn babies. Proficiency at intubation has declined markedly in recent decades such that fewer than half of babies are successfully intubated at the first attempt. Laryngoscopy is the crucial part of endotracheal intubation. Traditionally, operators use a standard laryngoscope to view the larynx by looking directly into the mouth (direct laryngoscopy). More recently videolaryngoscopes that have a video camera mounted at the tip of the laryngoscope blade have been developed, Rather than look directly into the mouth, the operator looks at a screen that displays the view acquired by the camera (indirect laryngoscopy). Videolaryngoscopes have been demonstrated to be useful for teaching trainees direct laryngoscopy, i.e. a senior colleague can coach them during the procedure. However, it may be that all clinicians are more successful with a videolaryngoscope. We will compare whether clinicians who are randomly assigned to intubate newborn infants using a videolaryngoscope are more successful in intubating newborn infants at the first attempt compared to clinicians who are randomly assigned to intubate newborn infants using a standard laryngoscope.

The investigators will study newborn infants who are undergoing intubation at the discretion of their treating clinicians in delivery room or in the Neonatal Intensive Care Unit (NICU).Term and preterm infants of any gender will be eligible to participate. Babies with upper airway anomalies will be ineligible. Participants will be randomly assigned in a 1:1 ratio to "VIDEO" or ""STANDARD" group. Intubation success will be determined in both groups using an exhaled carbon dioxide detector or flow sensor. Caregivers and outcome assessors will not be masked to group assignment. The investigators will enrol 214 babies to the study.

Enrollment

214 patients

Sex

All

Ages

Under 28 days old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Newborn infants (term and preterm, of any gender) in whom endotracheal intubation is attempted in the course of their clinical care in the Delivery Room or Neonatal Intensive Care Unit.

Exclusion criteria

  • Infants with upper airway anomalies

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

214 participants in 2 patient groups

Videolaryngoscope
Experimental group
Description:
Intubation attempted with C-MAC videolaryngoscope
Treatment:
Device: Videolaryngoscopy
Standard laryngoscope
Active Comparator group
Description:
Intubation attempted with standard laryngoscope
Treatment:
Device: Direct laryngoscopy

Trial contacts and locations

1

Loading...

Central trial contact

Colm PF O'Donnell, MB PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location