ClinicalTrials.Veeva

Menu

VINTAGE (Ventricular Intramyocardial Navigation for Tachycardia Ablation Guided by Electrograms) Using Commercial Off-The-Shelf (COTS) Catheters

National Institutes of Health (NIH) logo

National Institutes of Health (NIH)

Status

Begins enrollment this month

Conditions

Ventricular Arrhythmia

Treatments

Device: VINTAGE (Ventricular Intramyocardial Navigation for Tachycardia Ablation Guided by Electrograms)

Study type

Interventional

Funder types

NIH

Identifiers

NCT06940752
002320-H
10002320

Details and patient eligibility

About

Background:

Ventricular arrhythmia is an abnormal pulse rhythm that starts in the lower part of the heart (ventricles). Treatment includes ablation; ablation uses heat to destroy small portions of the heart that are causing short circuits in the normal heartbeats. But ablation does not always work well because some parts of the heart are hard to reach with current tools. Researchers want to try a new method called VINTAGE (ventricular intramyocardial navigation for tachycardia ablation guided by electrograms). VINTAGE may be better able to treat portions of the heart that are harder to reach with standard techniques.

Objective:

To test VINTAGE in people with ventricular arrhythmia.

Eligibility:

People aged 21 years and older with ventricular arrhythmia that did not respond to standard treatment.

Design:

Participants will have baseline tests. They will have blood tests and tests of their heart function. They will have imaging scans. They will complete a health questionnaire.

Participants will undergo the VINTAGE procedure. They will be either completely or partially asleep. Doctors will insert tubes through large blood vessels in the groin. Tubes may also be inserted through the chest and wrist. They will use x-rays and ultrasound to guide tubes and guidewires directly into the heart muscle to do the ablation.

Participants will stay in the hospital 1 or more nights after the procedure.

Participants will have 3 follow-up visits over 6 months. These visits are for standard care after heart ablation. They will include blood tests, imaging scans, and tests of heart function. Participants may also wear a device to monitor their heart rhythms at home.

Full description

Ventricular arrhythmias cause heart damage or death. Ventricular arrhythmias usually arise from small zones of the heart that contribute a short circuit or errant stimulus. Ventricular arrhythmias may be reduced or abolished by non-surgical catheter procedures to heat and destroy the small portions of the heart that contribute a short circuit or abnormal pacemaker. However, not all portions of the heart can physically be reached for catheter treatment.

We have developed a new non-surgical catheter approach called VINTAGE (Ventricular Intramyocardial Navigation for Tachycardia Ablation Guided by Electrograms) to treat ventricular arrhythmias arising from difficult-to-reach portions of the heart. In VINTAGE, catheter tools are moved inside the walls of the beating heart to reach treatment targets. In a small number of patients who failed prior catheter treatment of ventricular arrhythmia, VINTAGE effectively suppressed the ventricular arrhythmia or abnormal pacemaker in most.

The purpose of this research protocol is to test VINTAGE more carefully in people with ventricular arrhythmias who have failed prior catheter ablation. In this protocol, we will use catheter tools that are commercially available but are not designed or approved for use in VINTAGE.

Enrollment

30 estimated patients

Sex

All

Ages

21 to 100 years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

  • INCLUSION CRITERIA:

Candidates must meet all of the following criteria:

  • Age >= 21 years

  • Undergoing planned repeat radiofrequency catheter ablation for ventricular arrhythmias (Having failed a previous attempt at catheter ablation and at least one antiarrhythmic drug for ventricular arrhythmias)

  • Ventricular arrhythmia COHORT 1:

    • Monomorphic ventricular tachycardia
    • Has an implanted cardioverter defibrillator (ICD)
    • Hospital admission for ventricular tachycardia since most recent ablation attempt
  • Ventricular arrhythmia COHORT 2:

    --Monomorphic (unifocal), frequent, premature ventricular contraction, >=15% burden

  • Naive pericardium (no prior cardiac surgery)

  • Either of

    • Symptomatic (intolerable palpitation, syncope, fatigue, dyspnea, heart failure, hospital admission for ventricular arrhythmia, appropriate ICD discharge, appropriate antitachycardia pacing), OR
    • Left ventricular ejection fraction < 0.50
  • Willing to return for all scheduled follow-up activities, and eligible or able to undergo required protocol and testing

EXCLUSION CRITERIA:

  • Does not consent to participate, or unable to consent to participate
  • Left ventricular ejection fraction < 0.20
  • Hemodynamic instability or emergency procedure
  • Requires planned temporary mechanical circulatory device (such as percutaneous left ventricular assist device or intraaortic balloon counterpulsation pump)
  • Pregnant
  • eGFR < 30 mL/min/1.73m^2 or end-stage renal failure requiring renal replacement therapy
  • Survival despite successful procedure expected < 6 mo

Trial design

Primary purpose

Device Feasibility

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

30 participants in 1 patient group

VINTAGE Arm
Experimental group
Description:
Non-surgical catheter approach called VINTAGE will be used to treat ventricular arrhythmias arising from difficult-to-reach portions of the heart.
Treatment:
Device: VINTAGE (Ventricular Intramyocardial Navigation for Tachycardia Ablation Guided by Electrograms)

Trial contacts and locations

1

Loading...

Central trial contact

Annette M Stine, R.N.; Robert J Lederman, M.D.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems