ClinicalTrials.Veeva

Menu

Weaning Preterm Infants at 1500 Grams From Incubators

T

Tel Aviv Sourasky Medical Center

Status

Completed

Conditions

Preterm Infants

Treatments

Behavioral: Weaning Preterm Infants from an incubator

Study type

Interventional

Funder types

Other

Identifiers

NCT01083303
TASMC08BI05089CTIL

Details and patient eligibility

About

Background: The weight at which infants are weaned from incubators varies among neonatal units.

Objective: To determine the effect on weight gain, temperature stability and resting energy expenditure (REE) of weaning infants at body weight of 1500 g versus 1600 g.

Design/Methods: infants will be randomized to incubator weaning at the weight of 1500 g or 1600 g. Preterm infants 1500 g birth weight, fully enterally fed, and without supplemental oxygen, at the postnatal age of 2 weeks will be included. Infants will be weaned to a warming bassinet (Babytherm 8000, Dräger) set to keep a mattress temperature of 37°C while decreasing it gradually to room temperature. Failure to wean is defined as core body temperature of < 36.1°C. Data collection included skin and rectal temperature obtained before weaning, and at 1/2, 1, 2, 6, 24, and 48 hours after weaning, weekly weight gain (g/kg/d). REE (kcal/kg/24h) will be measured by indirect calorimetry (Deltatrac II, Finland) before and 24 hours after weaning.

Full description

Eligible infants will be randomized by computer generated random numbers, to either the study group weaned at 1500 g or the control group weaned at 1600 g. Both groups will be weaned to a warming bassinet (Babytherm 8000, Drager). The Babytherm 8000 WB is an open care infant warming system with a warmed gel mattress with temperature control . The system is set to keep the mattress temperature of 37 degrees Celsius while decreasing it gradually to 32 0C and shutting the system off. On transfer to the Babytherm infants are dressed with a hat and two vests. Only after the infant maintained a normal body temperature under these conditions he could be transferred to an open bassinet. Failure to wean was defined as core body temperature of <36.10C.

Data collection included skin and rectal temperature obtained before weaning, and at 1/2, 1, 2, 6, 24, and 48 hours after weaning, daily and weekly weight gain (g/kg/d). Resting Energy Expenditure- REE (kcal/kg/24h) is measured by indirect calorimetry (Deltatrac II, Finland) before and 24 hours after weaning to the warming bassinet.

Data Collection included: PR temperature after 30 min, 60 min, 2 hours, 6 hours, 24 hours, after which temperatures were taken 4-hourly until 48 hours (degrees C), skin (axillary) temperature (degrees C), after 30 min, 60 min, 2 hours, 6 hours, and than again every 4 hours until 48 hours. REE (kcal/kg/24h)rate of hypothermia requiring return to the incubator, weight gain after 24 hours of weaning and over 1 week.( g/kg/d),time to discharge ( days).

Enrollment

21 patients

Sex

All

Ages

14+ days old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • stable preterm infants weighing ≤1500 g
  • fully enterally fed, and without supplemental oxygen
  • steroid or antibiotics treatment
  • at the postnatal age of ≥ 2 weeks were included
  • infants < than 2 weeks of age

Exclusion criteria

  • ventilated infants or those requiring oxygen supplementation
  • parenteral nutrition
  • antibiotic treatment or steroids treatment were excluded

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Factorial Assignment

Masking

None (Open label)

21 participants in 2 patient groups

weaning at 1500 g
Experimental group
Description:
weaning infants from an incubator at 1500 g
Treatment:
Behavioral: Weaning Preterm Infants from an incubator
weaning at 1600 g
Active Comparator group
Description:
weaning infants from an incubator at 1600 g
Treatment:
Behavioral: Weaning Preterm Infants from an incubator

Trial contacts and locations