ClinicalTrials.Veeva

Menu

Which is the Best Bedside Test to Detect Endobronchial Intubation?

Medical University of Vienna logo

Medical University of Vienna

Status

Completed

Conditions

Endobronchial Intubation

Treatments

Other: All three
Other: Auscultation
Other: Observation of symmetric chest movements
Other: Tube depth

Study type

Interventional

Funder types

Other

Identifiers

NCT01232166
MUW464/2003

Details and patient eligibility

About

Background: Endotracheal intubation has become a well established standard in protecting the airway during surgical procedures, and in emergency situations. Serious complications can occur from the incorrect placement of an endotracheal tube in a mainstem bronchus. If unrecognized it can lead to hypoxemia secondary to atelectasis of the unventilated lung and hyperinflation of the intubated lung, which can result in barotrauma. As bedside method the golden standard to verify the correct endotracheal tube placement is bilateral ausculation of the chest. However this is not always satisfactory, as breath sounds can be transmitted to the opposite side of the chest in spite of endobronchial intubation. Therefore other clinical tests to verify the correct endotracheal tube placement have become part of daily clinical practice, like observation of symmetric chest movements, and use of the cm markings printed on the endotracheal tube. However so far no study investigated which of these bedside clinical methods works best in detecting an inadvertently placed endobronchial tube in adults. We therefore designed a study to compare three different bedside methods to verify endotracheal or endobronchial tube placement.

Objective: To determine which of four commonly used bedside methods of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity.

Design: Prospective randomized, blinded study. Setting: Tertiary, academic hospital, department of anaesthesia. Participants: 160 consecutive ASA I or II patients, aged 19-75 years, scheduled for elective gynaecological or urological surgery.

Interventions: Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube (ETT) was fiberoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. First-year residents and experienced anaesthesiologists independently performed one of the following randomly assigned bedside tests in each patient in an effort to determine whether the tube was properly positioned in the trachea: 1) bilateral auscultation of the chest (Auscultation); 2) observation and palpation of symmetric chest movements (Observation); 3) estimating the position of the ETT by the insertion depth (Tube Depth); and, 4) a combination of all three mentioned tests (All Three).

Main outcome measures: Correct and incorrect judgements of endotracheal tube (ETT) position as independently assessed by first-year anaesthesia residents and experienced anaesthesiologists with each of the four bedside tests.

Enrollment

160 patients

Sex

All

Ages

19 to 75 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

ASA I or II patients, aged 19-75 years, scheduled for elective gynaecological or urological surgery that needs endotracheal intubation.

Exclusion criteria

  • Pre-existing lung disease, pleural effusion, anticipated difficult airway, known endobronchial or tracheal lesions, or patients at risk for aspiration of gastric contents.

Trial design

Primary purpose

Diagnostic

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

160 participants in 8 patient groups

Endobronchial Intubation, Auscultation
Experimental group
Description:
In this arm, the endotracheal tube will be positioned in the right main stem bronchus under direct visualization through a fiberoptic bronchoscope. The study anesthesiologists will then perform bilateral auscultation of the lungs only, with the patient's thorax and head covered with blankets to blind participants to thorax movements and ETT insertion depth (Group Auscultation, n=20)
Treatment:
Other: Auscultation
Endobronchial Intubation, Observation
Active Comparator group
Description:
In this arm, the endotracheal tube (ETT) will be positioned in the right main stem bronchus under direct visualization through a fiberoptic bronchoscope. To determine the position of the ETT the study anesthesiologists will then perform observation and palpation of symmetric chest movements without auscultation of the lungs, with the patient's head covered with blankets to blind participants to ETT insertion depth (Group Observation, n=20);
Treatment:
Other: Observation of symmetric chest movements
Endobronchial intubation, tube depth
Active Comparator group
Description:
In this arm, the endotracheal tube (ETT) will be positioned in the right main stem bronchus under direct visualization through a fiberoptic bronchoscope. To determine the position of the ETT the study anesthesiologists will then estimate ETT position by observing the ETT cm scale without lung auscultation, with the patient's thorax covered by blankets to blind participants to thorax movements (Group Tube Depth, n=20)
Treatment:
Other: Tube depth
Endobronchial intubation, all three
Active Comparator group
Description:
In this arm, the endotracheal tube (ETT) will be positioned in the right main stem bronchus under direct visualization through a fiberoptic bronchoscope. To determine the position of the ETT the study anesthesiologists will then perform a combination of auscultation, observation and tube depth
Treatment:
Other: All three
Endotracheal Intubation, Auscultation
Experimental group
Description:
In this arm, the endotracheal tube will be positioned in the trachea, 2,5-4cm above the carina under direct visualization through a fiberoptic bronchoscope. The study anesthesiologists will then perform bilateral auscultation of the lungs only, with the patient's thorax and head covered with blankets to blind participants to thorax movements and ETT insertion depth (Group Auscultation, n=20)
Treatment:
Other: Auscultation
Endotracheal Intubation, observation
Active Comparator group
Description:
In this arm, the endotracheal tube (ETT) will be positioned in the trachea, 2,5-3cm above the carina under direct visualization through a fiberoptic bronchoscope. To determine the position of the ETT the study anesthesiologists will then perform observation and palpation of symmetric chest movements without auscultation of the lungs, with the patient's head covered with blankets to blind participants to ETT insertion depth (Group Observation, n=20);
Treatment:
Other: Observation of symmetric chest movements
Endotracheal intubation, tube depth
Active Comparator group
Description:
In this arm, the endotracheal tube (ETT) will be positioned in the trachea, 2,5 - 4 cm above the carina under direct visualization through a fiberoptic bronchoscope. To determine the position of the ETT the study anesthesiologists will then estimate ETT position by observing the ETT cm scale without lung auscultation, with the patient's thorax covered by blankets to blind participants to thorax movements (Group Tube Depth, n=20)
Treatment:
Other: Tube depth
Endotracheal intubation, all three
Active Comparator group
Description:
In this arm, the endotracheal tube (ETT) will be positioned 2,5-4cm above the carina under direct visualization through a fiberoptic bronchoscope. To determine the position of the ETT the study anesthesiologists will then perform a combination of auscultation, observation and tube depth
Treatment:
Other: All three

Trial contacts and locations

0

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems