This is an observational, prospective, non-randomized collection of defined clinical data under normal conditions of use for the WiCS-LV System, an implantable cardiac pacing system capable of delivering pacing energy to the left ventricle of the heart without using a pacing lead.
Patients will be enrolled and followed according to standard of care for 5 years.
Full description
A clinical registry will be used to collect data from all implanted patients, at all follow-ups and across all implanting centers. Implant procedure will be according to the 'Instruction for Use' of the system and assessments and follow-ups according the best clinical practice.
Anonymized data will be collected on Case Report Forms (CRF) for each patient in the registry. These data will be collected at the time of implant and at scheduled patient in-clinic follow-ups of 1 week, 3 months, 6 months, and 1, 2,3,4,5 years post implant. Patients entering the registry will be given a Registry code suitable to uniquely identify the patient, the implanting center, and the responsible physician.
Data will be consolidated into a dataset by the sponsor for analysis purposes. The sponsor may request support from the center to review patient records in order to monitor the data in cases where the data appears incomplete or appears to be inaccurate.
The data set will be consolidated such that each implanting center may access its own data, or as mutually agreed between centers, aggregate data. Data may be used by centers for purposes of publication or other objectives of the center.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Patients with heart failure meeting standard criteria for CRT based upon the current European Society of Cardiology / European Heart Rhythm Association (ESC/EHRA) guidelines and meeting criteria in one of these categorizations:
Untreated by conventional CRT:
This includes:
Non-responder to conventional CRT
This includes:
• Patients with a previously implanted CRT device who based on prescribing physician judgment experience no change or worsening of heart failure symptoms or no change or worsening of NYHA functional class after 6 months of CRT treatment.
Upgrade:
This includes:
Exclusion criteria
Triple anticoagulation therapy (warfarin, clopidogrel, ASA, or other agents) Stage 4 or 5 renal dysfunction defined as GFR <30 Grade 4 mitral valve regurgitation Thrombocytopenia (platelet count <150,000) Non-ambulatory (or unstable) NYHA class 4 Contraindication to heparin Contraindication to both chronic anticoagulants and antiplatelet agents Contraindication to iodinated contrast agents Insufficient acoustic window to the LV as assessed from diagnostic transthoracic echocardiography Left atrial or left ventricular thrombus Attempted implant of a Pacemaker, ICD, or CRT device within 3 days Life expectancy < 12 months Chronic hemodialysis Myocardial infarction within one month Major cardiac surgery within one month Incompatible electrical stimulation therapy devices, for example transcutaneous electrical nerve stimulation (TENS) or other neurological stimulation devices Exposure to magnetic resonance imaging (MRI) Use of diathermy Use of therapeutic ultrasound Use of echocardiography imaging using vascular, intracardiac, Doppler, and trans-esophageal probes and systems Use of ionizing radiation treatments